3813.2.2 Freeze Prevention Control1 .Frequency of the compressorFor prevention of freezing of the indoor evaporator, the frequency of the compressor will be changed accordingto the indoor piping temperature.2 .Indoor Fan ControlIndoor fan speed changes according to the indoor piping temperature.13.2.3 Dew Prevention Control• To prevent dew formation at indoor unit discharge area.• This control starts if all conditions continue for 20 minutes:- Operated with Cooling or Soft Dry Mode.- Indoor intake temperature is between 25к and 29к.- Outdoor air temperature is less than 30к.• This control stopped then receive air swing change signal from Remote Control.13.2.4 Overload Protection For Cooling OperationThe frequency for the compressor will change according to the outdoor piping temperature.13.3 Indoor Piping Air Temperature Control (Heating)13.3.1 Indoor Fan Control1. Indoor fan is controlled by the indoor piping temperature.ϥ Manual Fan SpeedPiping Temperature(к)K0 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K1116 19 24 32 32 36 36 39 54 54 57 6063к.Outdoor pipe Temp.61к60к56кRE9JKE, RE12JKERE15JKE58к9к.8к.6к.0к.Max:40 Hz Min 30Hz