Indoor UnitRandom Auto Restart Control• Operation is restarted randomly after powerfailure at previous setting mode.Anti-Freezing Control• Anti-Freezing control for indoor heatexchanger. (Cooling and Soft Dry)Ionizer Control• Ionizer control for generate negative ion indischarge air.Indoor Fan Speed Control• High, Medium and Low.• Automatic Fan Speed Mode– Heating : Fan speed varies from Me →SSLo in accordance withindoor heat exchanger.– Cooling : Fan rotates at Hi, Me and SLospeed. Deodorizing control isavailable.– Soft Dry : Fan rotates at Lo- speed.Deodorizing control isavailable.• Automatic air swing and manual adjustedby remote control for vertical airflow.• Manually adjusted by hand for horizontalairflow.Airflow Direction ControlAutomatic Operation Button• Press for < 5s to operate Automaticoperation mode.(Used when the remote control cannot be used.)• Press continuously for 5s or < 10s tooperate Test Run/Pump down. “Beep”sound will be heard at the 5th second.(Used when test running or servicing.)• Press continuously for 10s and above toomit or resume the remote control signalreceiving sound. “Beep, beep” sound willbe heard at the 10th second.AUTOOFF / ONOperation Indication Lamps (LED)• POWER (Green) ......... Lights up in operation,blinks in AutomaticOperation Mode judging.• QUIET (Orange) ......... Lights up in Quiet ModeOperation.• TIMER (Orange) ......... Lights up in TimerSetting.• POWERFUL (Orange) ... Lights up in PowerfulMode Operation.• (Green) ............ Lights up in IonizerMode Operation.Operation Mode• Heating, Cooling, Soft Dry and AutomaticMode.Powerful Operation• Reaches the desired room temperaturequickly.Time Delay Safety Control• Restarting is inhibited for appro. 3 minutes.Starting Current ControlQuiet Operation• To provide extra quiet operation.7 Minutes Time Save Control• Cooling Operation only.• Fan motor is delayed for 1.6 seconds whencompressor starts simultaneously.30 Minutes Time Save Control• Heating Operation only.Hot-Start Control• At Heating Operation the indoor fan willoperate at SLo speed when indoor heatexchanger temperature reaches 30°C.Anti Cold Draft Control• The indoor fan operates at SSLo when theindoor heat exchanger temperature is low.(During Heating mode thermal off)4CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oywww.ilmalämpöpumput.com