9917. Technical DataTechnical data provided are based on the air conditioner running under free frequency.17.1 Cool Mode Performance DataUnit setting: Standard piping length, Hi Fan, Cool mode at 16°CVoltage: 230V17.1.1 CS-YE9QKE/CU-YE9QKE CS-UE9QKE/CU-UE9QKEIndoor (°C) Outdoor DB (°C)5 16 25 35DB WB TC SHC IP TC SHC IP TC SHC IP TC SHC IP19.0 2525 2328 546 2711 2341 407 2546 2293 546 2500 2387 72027 22.0 2854 1732 443 2800 1673 405 2778 1610 522 2449 1525 70715.7 2547 2522 486 2404 2380 455 2306 2283 560 2120 2098 73023 18.4 2504 1656 513 2543 1657 439 2534 1623 545 2174 1574 72013.3 1954 1934 430 1574 1559 201 1782 1764 423 1948 1928 73220 15.8 2057 1491 408 2043 1460 387 2257 1588 558 1979 1511 725(Dry bulb value based on 46% humidity)17.1.2 CS-YE12QKE/CU-YE12QKE CS-UE12QKE/CU-UE12QKEIndoor (°C) Outdoor DB (°C)5 16 25 35DB WB TC SHC IP TC SHC IP TC SHC IP TC SHC IP19.0 3535 2919 827 3796 2935 615 3564 2874 827 3500 2993 109027 22.0 3995 2171 670 3920 2098 612 3890 2018 791 3428 1912 107115.7 3566 3530 736 3366 3333 689 3228 3196 848 2967 2938 110523 18.4 3505 2076 776 3561 2077 665 3547 2035 826 3044 1973 108913.3 2735 2708 651 2204 2182 305 2495 2470 641 2727 2699 110820 15.8 2879 1869 617 2860 1830 586 3160 1991 845 2771 1894 1098(Dry bulb value based on 46% humidity)17.1.3 CS-UE18QKE/CU-UE18QKEIndoor (°C) Outdoor DB (°C)5 16 25 35DB WB TC SHC IP TC SHC IP TC SHC IP TC SHC IP19.0 5535 4070 1067 5443 4070 1061 5064 3848 1333 5000 4043 154027 22.0 5669 3066 1122 5871 3238 1064 5507 3045 1348 5076 2324 156015.7 4957 3899 1130 5047 3919 1061 4685 3766 1308 4209 3584 162623 18.4 5357 2968 1180 5508 3093 1063 5150 2931 1322 4634 2759 165613.3 4123 3589 964 4412 3730 888 4388 3726 1307 3882 3447 159820 15.8 4865 3061 828 5895 3441 1439 5259 3189 1678 4336 1533 1740(Dry bulb value based on 46% humidity)TC - Total Cooling Capacity (W)SHC - Sensible Heat Capacity (W)IP - Input Power (W)