Vertical Airflow Direction Auto-Control•••• When set an Airflow Direction Auto-Control with remotecontrol, the louver swings up and down as shown in thediagram.•••• The louver does not swing when the Indoor Fan Motorstops during operation at the upper limit.•••• When stopped with remote control, the discharge vent isreset, and stopped at the closing position.•••• During Anti-dew condensation prevention, Airflow DirectionAuto-control angle change from 0° - 36° to 12° - 28° underCooling and Soft Dry operation mode.Vertical Airflow Direction manual Control•••• When the manual Airflow Direction Selection Button ispressed, the automatic airflow is released and the airflowdirection louver move up and down in the range shown inthe diagram.The louver can be adjusted by pressing the button to thedesired louver position.•••• When the remote control is used to stop the operation, thedischarge vent is reset, and stopped at the closing position.•••• During Anti-dew condensation prevention, Airflow DirectionManual control angle change from 14°, 19°, 24°, 30°, 36° to16°, 18°, 20°, 22°, 24° under Cooling and Soft Dry operationmode.Horizontal Airflow Direction Auto-Control•••• When set an Airflow Direction Auto-Control with remotecontrol, the vanes swings left and right as shown in thediagram.•••• The vanes does not swing when the Indoor Fan Motor stopsduring operation at 22° angle.•••• When stopped with remote control, the discharge vent isreset, and stopped at the reset position.•••• During Anti-dew condensation prevention, Airflow DirectionAuto-control angle change from 0° - 44° to 14° - 30° underCooling and Soft Dry operation mode.8.8. Airflow Direction Control1. There is no swinging while indoor fan motor is stopped during Cooling, Ion and Soft Dry operation.1. There is no swinging while indoor fan motor is stopped during Cooling, Ion and Soft Dry operation.26CS-C18CKV CU-C18CKV / CS-C24CKV CU-C24CKV