Horizontal Airflow Direction manual Control•••• When the manual Airflow Direction Selection Button ispressed, the automatic airflow is released and the airflowdirection vane move left and right in the range shown in thediagram.The louver can be adjusted by pressing the button to thedesired vane position.•••• When the remote control is used to stop the operation, thevanes is reset, and stopped at reset position.•••• During Anti-dew condensation prevention, Airflow DirectionManual control angle change from 0°, 11°, 22°, 33°, 44° to14°, 18°, 22°, 26°, 30° under Cooling and Soft Dry operationmode.8.9. Delay ON Timer Control•••• When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so thatthe room will reach nearly to the set temperature by the desired time.•••• For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.•••• For Automatic mode, the indoor fan will operate at SLo speed for 20 seconds, 15 minutes before the set time to detect theintake air temperature to determine the operation mode. The operation indication lamp will blink at this time.8.10. Remote Control Signal Receiving Sound•••• Long beep sound will be heard when:-−−−− Stopping the Air Conditioner using ON/OFF switch.−−−− Stopping the Quiet Mode.−−−− Stopping the Powerful Mode.−−−− Stopping the Ion Mode.•••• Short beep sound will be heard for others.•••• To switch off the beep sound:-Press the “Automatic Operation Button” continuously for 10 seconds or more (“beep” “beep” will be heard at the 10th second).Repeat the above if you want to switch ON the beep sound.However, if the “Automatic Operation Button” has been pressed the Automatic operation will be activated.If you do not require this operation, you may change it by using the remote control.27CS-C18CKV CU-C18CKV / CS-C24CKV CU-C24CKV