– 1 –CW-C241SEWARNINGThis service information is designed for experienced repair technicians only and is not designed for use by the generalpublic. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attemptingto service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians.Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injuryor death.Precaution of Low TemperatureIn order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigeration circuit.PRODUCT SPECIFICATIONSMODELCAPACITY (Btu/h) 22,510–22,510(W) 6,600–6,600MOISTURE REMOVAL (s/h) 4.0(Pints/h) 8.5AIR CIRCULATION (m 3/min) 17.0(Cft/min) 600ELECTRICAL DATA Phase Ø SingleCycle (Hz) 50Voltage (V) 230–220VRunning Current (A) 14.5–14.4Starting Current (A) 60Input (W) 3,000–2,950COMPRESSOR OUTPUT (W) 2,200CABINET Height (mm) 16–7/8" (428)DIMENSIONS Width (mm) 26" (660)Depth (mm) 28–3/4" (730)NET WEIGHT (kg) 72(lbs) 160REFRIGERANT (R–22) (g) 1,350(oz) 47.758–57CW-C241SENOISE LEVELHighLowIndoor (dB)Outdoor (dB)Indoor (dB)Outdoor (dB)* Specifications are subject to change without notice for further improvement.67–6654–5364–63