268.2.4.2. (VHS) Condition for clearing the self-diagnosis history1. A case of that press the FF key and the EJECT key simultaneously over 5 seconds.2. A case of that the factory jumper (TW1004) is shorted.8.2.4.3. (VHS) Indication of the self-diagnosis history.1. The self-diagnosis histories and its supplementary data could be indicated on the FIP with Service mode of number from 3 to5.2. The procedure of setting the service mode and the format if the indication are same as usual.Both the Error numbers and its supplementary data of history 1, 2and 3 are indicated by selecting the Service mode 3, 4 and 5 asshown above.In case of that any Error has not been memorized, the Error number and its supplementary data is indicated as " - ".8.2.4.4. (VHS) Display of Supplementary Data 3 and 4During displaying the Self-Diagnosis History, press [STOP] key on front panel to change the display.*Example of DisplayA: Service Mode Number.B: Supplementary Data 3...Mechanism process shifting Number.C: Supplementary Data 4...LM(Loading Motor information)*Display of means that " Loading Motor turns ON when [EJECT] button was pressed, but an error hasoccurred while mechanism was between REV position and LOAD position.[EJECT] [FF] [REW]10: PLAY → passing REV11: passing REV12: passing REV → LOAD(Capstan STOP)13: LOAD → DOWN14: DOWN → EJECT15: EJECT completionU0: PLAY → STOP FU1: STOP F → FFU2: FF starting upA0: PLAY → STOP FA1: STOP → REWA2: REW starting up[PLAY] [REC] [STILL]20: Cylinder starting up, Phase drawing 30: Cylinder starting up, Phase drawing 40:Turning forward21: Audio muting, VV selection 31: REC signal output 41:Speed is 0, Capstan is OFF[P.ON] [STILL → PLAY] [CUE]-- Process of turning on power 48: Tape sending 49: x2 speed sending, Turning point of Calcu-lating remains[P.OFF] [CUE → PLAY] [REV]70: PLAY → P.OFF 4A: Finishing edge Checking, Tape sending 80: PLAY → P.OFF4-: PLAY Checking, Tape sending 81: RewindingP.OFF → REV