95DP-2330/3030DEC 2004Ver. 2.0DP-2310/301015 Not Used16 Side Adjust (ADU) Adjustment of LSU side-side (ADU). -8 - +70.5mm17 Charge Roller Voltage Charge voltage compensation adjustment. -76 - +762.60V18 Standard Laser Power Laser power compensation adjustment. -29 - +2519 Std Bias DC Voltage Adjustment of bias standard voltage. -77 - 763.92V20 Not Used21 TDC Gain Voltage Adjustment of toner density sensor gainvoltage.-86 - +400.033V22-24 Not Used25 Bias Duty Ratio(Factory use only)Bias duty ratio adjustment -5 - +50.80%26 TDC Judgment Level Adjustment of toner supply starting judgementvoltage level.-26 - +2619.5mV27 Bias Frequency(Factory use only)AC Bias frequency adjustment -5 - +328 QUANTUM White Density Adjustment of standard white density level. -99 - +9929 QUANTUM Black Density Adjustment of standard black density level. -99 - +9930 Light Halftone Adj. Halftone duty ratio adjustment -127 - +12731 Fuser Temperature Adjustment of fuser temperature. -15 - +150.833°C32 Fuser Edge Temperature Temperature compensation for edges -15 - +150.833°C33 TDC Max. Read Only Set by Digital QUANTUM (QUARC) control -99 - +99(Read only)34 TDC Min. Read Only Set by Digital QUANTUM (QUARC) control -99 - +99(Read only)35 TDC Avg. Read Only Set by Digital QUANTUM (QUARC) control -99 - +99(Read only)36 Paper Loop (Tray 1) Individual Fine Adjustment for Tray 1 -99 - +9937 Not Used38 ID Standard Voltage Adjustment of judgement standard voltage. -35 - +3539 LSU Unit PWM Adjust Adjustment of PWM value of LSU. -32 - +3240 Transfer Current Side 1 Adjustment of Transfer Current. -16 - +150.6uA41 Paper Loop (Bypass) Individual Fine Adjustment for Sheet Bypass -99 - +9942 Paper Loop (Tray 2) Individual Fine Adjustment for Tray 2 -99 - +9943 Paper Loop (2-Sided) Adjustment for the length of the loop formedbefore the copier timing roller.-99 - +9944 FAX Laser Duty Adj Printer Density Adjustment for FAX.(-) : Darker.(+) : Lighter.-99 - +9945 Not Used46 PRINTER Laser Duty Adj Printer Density Adjustment for Printer.(-) : Darker.(+) : Lighter.-99 - +99F6 ModeNo. Item Remarks SettingRange