http://cxema.ruEB-GD35 EB-GD35C275.1.6. Output Level, Dynamic OperationGSM 900GSM 18005.1.7. Residual Peak PowerEqual to or less than 70 dBc (BW = 300 kHz)5.2. Rx Characteristics5.2.1. SensitivityGSM 900 Full Rate SpeechThe reference sensitivity performance in terms of frame erasure, bit error, or residual bit error rates (whichever is appropriate) isspecified in the following table, according to the propagation conditions.The reference sensitivity level is < -102 dBm.GSM 900 Half Rate SpeechThe reference sensitivity performance in terms of frame erasure, bit error, or residual bit error rates (whichever is appropriate) isspecified in the following table, according to the propagation conditions.Power ControlLevelTransmitter Output Power(dBm)Tolerance for Conditions (dB)Normal ExtremeTBAPower ControlLevelTransmitter Output Power(dBm)Tolerance for Conditions (dB)Normal ExtremeTBAChannels Propogation ConditionsTUhighPropogation ConditionsRAPropogation ConditionsHT Static ConditionsTest Limiterror rate%MinimumNo. ofsamplesTest Limiterror rate%MinimumNo. ofsamplesTest Limiterror rate%MinimumNo. ofsamplesTest Limiterror rate%MinimumNo. ofsamplesTCH/FS FER 6.742*α 8900 0.122*α 164000class Ib (RBER) 0.42/α 1,000,000 0.41/α 20,000,000class II (RBER) 8.33 120,000 7.5 24000 9.333 60000 2.439 8200NOTE: 1 < α < 1.6. The value of a can be different for each channel condition but must remain the same for FER andclass 1b RBER measurements for the same channel condition.Channels Propogation ConditionsTUhighPropogation ConditionsRAPropogation ConditionsHTTest Limiterror rate%MinimumNo. ofsamplesTest Limiterror rate%MinimumNo. ofsamplesTest Limiterror rate%MinimumNo. ofsamplesTCH/HS (FER) 4.598 13050TCH/HS class Ib (BFI=0) 0.404 148500TCH/HS class II (BFI=0) 7.725 25500 8500 20000 7600 20000TCH/HS (UFR) 6.250 9600TCH/HSL class Ib ((BFI or UFI)=0) 0.269 227000