Panasonic FX-301-F Instruction Manual
I/O CIRCUIT DIAGRAMS5%& Internal circuit Users’ circuit(Brown) +V (Note 1)(Blue) 0V (Note 1)100mA max. (Note 2)(Black) Output 12 to 24V DC±10%+-Color code of quick-connection cableTerminal No.Main circuitLoad%%& (Blue) 0V (Note 1)100mA max. (Note 2)(Black) OutputInternal circuit Users’ circuit(Brown) +V (Note 1)12 to 24V DC±10%+-Color code of quick-connection cableTerminal No.Main circuitLoadNotes: 1) The quick-connection sub cable does not have +V (brown) and 0V (blue).The power is supplied from the connector of the main cable. !^ '_`= "^ * >`#*^ RUN MODE79 When MODE indicator / RUN (green) lights up, the display setting or thesensitivity select setting can be checked.Refer to “ SENSITIVITY SELECTION FUNCTION” for further detailsof sensitivity select setting. ' &*9 When pressing Jog switch for 2 sec., or more, the display changes asper the diagram below. Operating in the high sensitivity mode.OrINDIVIDUAL TEACHING MODE89 When MODE indicator / TEACH (yellow) lights up, threshold value can beset on a single unit.The sensitivity selection function is set to the automatic sensitivity setting“ ” at the time of factory shipment. In case sensitivity selection set-ting is done, make sure to carry out “teaching” after the sensitivity selec-tion setting.For the sensitivity selection setting, refer to “ SENSITIVITY SELEC-TION FUNCTION.”Step Digital display Description1 { >,,!#) or liquid detection>,,.#).2{ Press MODE key to light up MODE indicator / TEACH (yellow).{Turn the jog switch to “+” or “–” side to set to either Leak(F7) mode “ ” or Liquid (F9) mode “ .”{In case Liquid (F9) mode “ ” is set, the model indi-cator (green) lights up.3{Press Jog switch in no-leak condition with leak detection(,,!#) or no-liquid condition with liquid detection(,,.#).Then, “ ” on the digital display moves from left to right.4{When teaching is accepted, the result of threshold valuesetting is displayed.In case stable sensing is possible:“ ” on the digital display (red) blinks 3 times.In case stable sensing is not possible:“ ” on the digital display (red) blinks. (Note 1)'{If the teaching result is “ ,” the sensor returns toRUN mode automatically and the incident light intensityis shown on the digital display (red).{MODE indicator / RUN (green) lights up.{The setting is complete.Notes: 1) For details, refer to “ ERROR INDICATION.”2) The initial setting at the time of factory shipment is Liquid (F9) mode “ .”COLLECTIVE TEACHING MODE99 When MODE indicator / ALL (yellow) lights up, a threshold value can be & Step Digital display Description1 {Insert leak detection fiber (,,!#) or liquid detection>,,.#).2{Press MODE key to light up MODE indicator / ALL (yellow).{Turn the jog switch to “+” or “–” side to set to either Leak(F7) mode “ ” or Liquid (F9) mode “ .”{In case Liquid (F9) mode “ ” is set, the model indi-cator (green) lights up.3{Press Jog switch in no-leak condition with leak detection>,,!#^ ~ - >,,.#). Then, “ ” on the digitaldisplay moves from top left to top right and from bottomright to bottom left (twice).4{When teaching is accepted, the result of threshold valuesetting is displayed.In case stable sensing is possible:“ ” on the digital display (red) blinks 3 times.In case stable sensing is not possible:“ ” on the digital display (red) blinks. (Note 1)'{If the teaching result is “ ,” the sensor returns toRUN mode automatically and the incident light intensityis shown on the digital display (red).{MODE indicator / RUN (green) lights up.{The setting is complete.Direction of transmission '^ & when the amplifiers in Leak (F7) mode “ ” and in Liquid mode (F9) mode“ ” are mixed in cascade connection.Notes: 1) For details, refer to “ ERROR INDICATION.”2) In collective teaching, only an instruction of the teaching operation is transmitted, the % 3) When the collective teaching is done, the following setting conditions are copied. In case anindividual setting condition is desired to be set, set it individually after the collective teaching.4) The collective teaching transmits the information only in the direction of the arrow shown on % mounted in cascade. Check the direction of the transmission before collective teaching is done.$ ~$# Mode Digit displayPercentage display Model setting Digital dis-play settingSensitivity se-lection function Timer function NO / NC selec-tion functionLeak (F7) mode - -Liquid (F9) mode OPERATION PROCEDURE69 When the power supply is switched on, normal condition is displayed[MODE indicator / RUN (green) lights up] and the digital display (red)shows the incident light intensity.9 When MODE key is pressed, the mode changes as per the diagrambelow. Further, if the jog switch is pressed for 3 sec., or more, in “ADJ,”“DISP” or “OUT” condition, SUB mode can be set.TEACHThreshold value can be set on a single amplifier.Refer to “ INDIVIDUAL TEACH-ING MODE.”8ADJAllows fine adjustment of the threshold value.Refer to “ THRESHOLD VALUEFINE ADJUSTMENT MODE.”10DISPThe digital display (red) can be switched to thelight up / eco / inverse mode.Refer to “ DIGITAL DISPLAY SET-TING MODE.”11OUTOutput can be compulsory changed to ON orOFF regardless of the incident light intensity.Refer to “ FORCED OUTPUT MODE.”12ALLThreshold value can be collectively set toamplifiers mounted in cascade.Refer to “ COLLECTIVE TEACH-ING MODE.”9MAIN modePress 3 sec.or moreRefer to “ SENSITIVITYSELECTION FUNCTION.”13Refer to “ NO/NCSELECTION FUNCTION.”15Press 3 sec.or more(Note)Press 3 sec.or more(Note)Refer to “ TIMERFUNCTION.”14SUB modePressPressPressPressPressPressRUNThis indicates normal sensing operation.Refer to“ RUN MODE.”7Note: In Liquied setting (F9 mode) only. |
Related manuals for Panasonic FX-301-F
Panasonic FX-301-F7 Instruction Manual
Panasonic FX-301 Series Instruction Manual
Panasonic FX-102P Instruction Manual
Panasonic EQ-34 Instruction Manual
Panasonic EX-FC1 Instruction Manual
Panasonic EX-F61 Instruction Manual
Panasonic GA-311 Instruction Manual
Panasonic EX-FC1 Instruction Manual
Panasonic PX-21 Instruction Manual
Panasonic LM10 Instruction Manual
manualsdatabase
Your AI-powered manual search engine