Panasonic FX-301-F Instruction Manual
THRESHOLD VALUE FINE ADJUSTMENT MODE109 When MODE indicator / ADJ (yellow) lights up, the set threshold value Step Digital display Description1 {Press MODE key to light up MODE indicator / ADJ (yellow).2{Turn Jog switch to “+” side, to increase the thresholdvalue.{Turn Jog switch to “–” side, to decrease the thresholdvalue.3 {When Jog switch is pressed, the changed threshold " 4{When MODE key is pressed 3 times, or for 1 sec., ormore, the sensor returns to RUN mode and the incidentlight intensity is shown in the digital display (red).{MODE indicator / RUN (green) lights up.{The setting is complete.Note: The adjustable area is limited as shown below. In order to adjust the threshold outside (100)ThresholdvalueLeak detection side11070Light amount (%)(100)ThresholdvalueLight amount (%)Adjustable areaAdjustable area13090Liquied present detection sideAdjustable area in Liquied (F9) mode: 90 to 130%Adjustable area in Leak (F7) mode: 70 to 110%DIGITAL DISPLAY SETTING MODE119 When MODE indicator / DISP (yellow) lights up, the digital display (red)can be switched to the light-up mode, eco mode or inverse mode.Step Digital display Description1 {Press MODE key to light up MODE indicator / DISP(yellow).2{When Jog switch is turned to “+” side or “–” side, themode in the digital display changes.: This is the light-up mode in the digital display(red).The digital display (red) always lights up.$ % ` &operation has not been done for 8 sec., or more,“ z@ &>^is turned off.When a key operation is done after the digital dis-play is turned off or when the collective teachingis carried out, the digital display (red) lights up.: This is the inverse mode of the digital display(red).In the normal display condition, the displaychanges to the inverse display and in the inversecondition, the display changes to the normal dis-play.3 {When Jog switch is pressed, the set display blinks 3 4{When MODE key is pressed twice or for 1 sec., or more,the sensor returns to RUN mode and the incident lightintensity is displayed in the digital display (red).{MODE indicator / RUN (green) lights up.{The setting is complete.Note: The initial setting at the time of factory shipment is the light-up mode “ .”FORCED OUTPUT MODE129 When MODE indicator / OUT (yellow) lights up, the output can be com-pulsory changed to ON or OFF regardless of the incident light intensity.Step Digital display Description1 {Press MODE key to light up MODE indicator / OUT (yellow).(Present output state is displayed.)2{When Jog switch is turned to “+” side or “–” side, theoutput is compulsory changed to ON or OFF.{ {When the output is compulsory changed to ON, the op-eration indicator (orange) lights up.3 {Press MODE key to return the sensor to Step 1.4{When MODE key is pressed, the sensor returns to RUNmode and the incident light intensity is displayed in thedigital display (red).{MODE indicator / RUN (green) lights up.SENSITIVITY SELECTION FUNCTION139 If Jog switch is pressed for 3 sec., or more, when MODE indicator / ADJ>& ^ &= & -sitivity, or set to automatic sensitivity.Note: The initial setting at the time of factory shipment is the automatic sensitivity setting“ .”Step Digital display Description1 {Press MODE key to light up MODE indicator / ADJ (yellow).2{Press Jog switch for 3 sec. or more.(The sensor goes into the sensitivity setting condition.){MODE indicator / RUN (green) blinks.3{When turning Jog switch to “+” side or “–” side, the digitaldisplay (red) and MODE indicator / RUN (green) blinks,and the sensitivity can be selected.: Automatic sensitivity settingAfter selecting the automatic sensitivity, the opti-mum sensitivity is set by carrying out teaching.: Low sensitivity setting: High sensitivity setting4 {When Jog switch is pressed, the setting display blinks 3 '{MODE indicator / TEACH (yellow) lights up and “ ”or “ ” is displayed in the digital display (red).{After sensitivity selection, carry out the teaching.For the setting method of teaching, refer to “ INDI-VIDUAL TEACHING MODE.”=?@K,Q=WZ[\,.] &^14Note: The initial setting at the time of factory shipment is the without timer condition “ .”9 The timer setting can be done by pressing the jog switch for 3 sec., ormore, when Liquid (F9) mode “ ” has been set and MODE indicator/ DISP (yellow) lights up. In case of Leak (F7) mode “ ,” the displaydoes not change to the timer function.For the selection method of Leak (F7) mode / Liquid (F9) mode, refer to“ INDIVIDUAL TEACHING MODE” or “ COLLECTIVE TEACHINGMODE.”9 This product incorporates a delay timer which reduces the effect of airbubbles, etc. TimeroperationSensingconditionNO/NCselection functionNC(Normal close)NC(Normal close)NO(Normal open)NormalDelay timerNO(Normal open)TLiquiedpresentLiquiedabsentONOFFONOFFONOFFONOFFTimer period: T = 10ms, 100ms, 1,000msTTT TTStep Digital display Description1{Confirm if the sensor is in Liquid (F9) mode “ ” in“ INDIVIDUAL TEACHING MODE” or “ COLLEC-TIVE TEACHING MODE.”2 {Press MODE key to light up MODE indicator / DISP (yellow).3{Press Jog switch for 3 sec., or more.(The sensor goes into the timer setting condition.){MODE indicator / RUN (green) blinks.4{When Jog switch is turned to “+” side or “–” side, thedigital display (red) and MODE indicator / RUN (green)blinks, and the timer period can be chosen.: Without timer: 10ms timer: 100ms timer: 1,000ms timer' {When Jog switch is pressed, setting display blinks 3 6 {The sensor returns to Step 2.7{When MODE key is pressed twice or for 1 sec., or more,the sensor returns to RUN mode and the incident lightintensity is displayed in the digital display (red).{MODE indicator / RUN (green) lights up.{The setting is complete. |
Related manuals for Panasonic FX-301-F
Panasonic FX-301-F7 Instruction Manual
Panasonic FX-301 Series Instruction Manual
Panasonic FX-102P Instruction Manual
Panasonic EQ-34 Instruction Manual
Panasonic EX-FC1 Instruction Manual
Panasonic EX-F61 Instruction Manual
Panasonic GA-311 Instruction Manual
Panasonic EX-FC1 Instruction Manual
Panasonic PX-21 Instruction Manual
Panasonic LM10 Instruction Manual
manualsdatabase
Your AI-powered manual search engine