INSTRUCTION MANUALDigital Fiber Sensor Amplifier FX-501□MJE-FX501C No.0052-92VThank you very much for purchasing Panasonic products.Please read this Instruction Manual carefully and thoroughly for the correct andoptimum use of this product.Kindly keep this manual in a convenient place for quick reference.WARNING● Never use this product as a sensing device for personnel protection.● In case of using sensing devices for personnel protection, use products whichmeet laws and standards, such as OSHA, ANSI or IEC etc., for personnelprotection applicable in each region or country.1 INTENDED PRODUCTS FOR CE MARKING● This product complies with the following standards / regulations.EMC DirectiveANSI/UL 60947-5-2, CAN/CSA C22.2 No.14S1-G-1-2009, S2-W-5-2009● Caution about UL recognitionIn case requiring conformity of UL listing mark or C-UL listing mark, USe class2 power supply unit.● Contact for CEPanasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15, 22525 Hamburg,Germany2 PART DESCRIPTIONMODE indicator: PRO (Yellow)MODE indicator: L / D (Yellow)Digital display(Green / Red)UP key• Teaching• Threshold valuefine adjustment• Select setting itemsSET key• Teaching• C o n f i r m s e t t i n gcontentsDOWN key• Teaching• Threshold value fineadjustment• Select setting itemsSensing outputoperation indicator(Orange)MODE key• Select Modes• Cancel during settingMODE indicator: CUST (Yellow)Pressing down SET key + MODE key for 3 sec : Set key lock or release key lock3 MOUNTINGHow to connect1. Fit the rear part of the mounting sec-tion of the amplifier on a DIN rail.2. Press down the rear part of themounting section of the unit on theDIN rail and fit the front part of themounting section to the DIN rail.How to remove1. Push the controller forward.2. Lift up the front part of the amplifierto remove it.2. Lift up1. Push forward2. Press down1. Fit35mm width DIN railHow to connect the fiber cableBe sure to fit the attachment to the fibers first before inserting the fibers to theamplifier. For details, refer to the instruction manual enclosed with the fibers.1. Snap the fiber lock lever down till itstops completely.2. Insert the fiber cables slowly into theinlets until they stops. (Note)3. Return the fiber lock lever to theoriginal position till it stops.Fiber lock leverFiber forreceiver1. Snap3. Return2. InsertFiber for emitterNote: With the coaxial reflective type fiber, such as , FD-G4 or FD-FM2, insert the single core fiber cable into thebeam-emitting inlet “P” and the multi-core fiber cable into the beam-receiving inlet.If they are inserted in reverse, the sensing performance will deteriorate.4 INSTALL MORE AMPLIFIER OF SERIES CONNECTION TYPE● Make sure that the power supply is OFF while adding or removing the seriesconnection type.● In case 2 or more the series connection types are connected in cascade,make sure to mount them on a DIN rail.● In case installing additional amplifier of series connection type, the maximum11 the series connection types using sub cables can be added to an amplifierusing a main connection cable.● When connecting 2 or more the series connection types in cascade, use thesub cable (optional) for the second series connection type onwards.For mounting and removing the amplifier, refer to “ MOUNTING.”How to cascade1. Mount the amplifiers, one by one,on the DIN rail.2. Slide the amplifiers next to eachother, and connect the quick-connection cables.3. Mount the end plates MS-DIN-E(optional) at both the ends to holdthe amplifiers between their flatsides.4. Tighten the screws to fix the endplates.How to Remove1. Loosen the screws of the endplates.2. Remove the end plates.3. Slide the amplifiers and removethem one by one. SlideCommunicationwindowSlideMain cable(Optional)Sub cable(Optional)End plateMS-DIN-E (Optional)End plateMS-DIN-E(Optional)5 I/O CIRCUIT DIAGRAMS+-12 to 24V DC%Main circuit (Brown) +V (Note)(Black) Sensing output(Blue) 0V (Note)LoadMain circuit (Brown) +V (Note)(Black) Sensing output(Blue) 0V (Note) Load+-12 to 24V DC%Note: The quick-connection sub cable does not incorporate +V (brown) and 0V (blue). The power is supplied fromthe connector of the main cable.231 Terminal No. Terminal name1 +V2 Sensing output3 0V6 OPERATION PROCEDUREThe changed settings are not stored if turning the power OFF whilesetting. Therefore, confirm the settings by pressing the SET key beforeturning the power OFF.● When turning ON the power, RUN mode is displayed and the digital displayshows the threshold value (green) and the incident light intensity (red).• Displays threshold value (green) and incident light intensity (red).• Teaching, threshold value fine adjustment and key lock functioncan be set.• For setting method of each function, refer to “ TEACHINGMODE,” “ THRESHOLD VALUE FINE ADJUSTMENT FUNC-TION,” or “ KEY LOCK FUNCTION.”• Select either Light-ON or Dark-ON.• For the setting, refer to “ SENSING OUTPUT OPERATIONMODE.”• The default setting is “ ” (Light-ON).• An item set in CUSTOM mode (Response time setting, Emissionpower setting and Hysteresis setting) is displayed.• For details, refer to “ CUSTOM MODE.”• The default setting is “ ” (response time setting).• Advanced setting can be done.• For the setting, refer to “ PRO MODE.”
Next |