MJE-FX411 No.0034-50VSPECIFICATIONSDisplayCommunication error has oc-curred at time of connection.The load has short-circuitedand excess current is flowing.Error description MeasuresTurn off the power, then check the load.Check if the mounted amplifiers are in close contactwith each other.ERROR DISPLAY INDICATOR READINGS10٨ Mode tableNotes: 1) This mode is not incorporated in the blue LED type and green LED type.2) While the peak / bottom hold mode is ON, the digital display is not turned off even if theEco mode is set to ON.The light emitting intensity can be switched among four levels.Timer settings can be select ed; Without timer / OFF-delay timer /ON-delay timer / ONE-SHOT timer. Also the timer period can be set.Emitting intensity selec-tion mode (Note 1)Timer setting modeThe display on the digital display can be inverted.Digital display inversion modeIf no key is pressed for approximately 20 sec. while in 'RUN' mode, thedigital display turns off automatically. Press the setting switch or movethe operation selection switch to make the display light up again. Thedigital display will light up when the threshold value adjuster is turned,but note that this will also cause the threshold value to change.Eco mode (Note 2)If the setting switch is pressed while'RUN' mode is active, the displaywill alternate between the peak hold value and the bottom hold value.(The display will refresh every 2 sec.) The display will return to nor-mal if any operation other than threshold value setting is carried out.Peak / Bottom hold modeResponse time change mode The response time can be set.Mode DescriptionFactorysettingMODE SELECTION7٨٨٨٨٨When the setting switch is pressed and held for 2 sec. or more, 'SET' mode (modesetting screen) is activated.If the setting switch is pressed while in 'SET' mode, the mode will change.If the threshold value adjuster is turned while a mode is active, the setting item will change and blink.When the setting switch is pressed at the item you would like to set, it blinks 3times and then the setting is confirmed and the mode switches to the next mode.If the setting switch is pressed and held for 2 sec. or more or do not press any key for15 sec. while 'SET' mode is active, the mode will switch automatically to'RUN' mode. 11٨٨Never use this product as a sensing device for personnel protection.In case of using sensing devices for personnel protection, use products whichmeet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-tion applicable in each region or country.WARNINGPART DESCRIPTION1Operation indicator (Orange)Digital display (Green)Threshold value (RUN condition)Stability indicator (Green)Threshold value adjuster (Note)Operation selection switchSetting switchIncident light intensity (RUN condition)Digital display (Red)CASCADING3٨٨٨٨٨٨٨٨٨Make sure that the power supply is off while adding or removing the amplifiers.Make sure to check the allowable ambient temperature, as it depends on thenumber of amplifiers connected in cascade.In case two, or more, amplifiers are connected in cascade, make sure to mountthem on a DIN rail.When the amplifiers move on the DIN rail depending on the attaching conditionor the amplifiers are mounted close to each other in cascade, fit them betweenthe optional end plates (MS-DIN-E) mounted at the two ends.Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.)When connecting more than two amplifiers in cascade, use the sub cable(CN-71-Cغ) as the quick-connection cable for the second amplifier onwards.When connecting amplifiers not close to each other in parallel, be sure to mountthe optional end plate (MS-DIN-E) at both sides of each amplifier or affix thecommunication window seal of the optional amplifier protection seal (FX-MB1) tothe communication windows. For details, refer to the instruction manual enclosedwith the FX-MB1.When the connector type and the cable type or different LED (red / blue / green)types are connected in cascade, mount the identical models together.When this product is used with the other digital fiber amplifiers, be sure to placethis product to the left most position (When you look from the connector side). Ifthis product is not placed to the leftmost position, this product may not operateproperly.Make sure that the power supply is off while connecting disconnecting the amplifi-ers and the quick-connection cables.MOUNTING2Ԙ35mm width DIN railԙԘԙԘԙFit the rear part of the mounting section of the amplifieron a DIN rail.Press down the rear part of the mounting section of theunit on the DIN rail and fit the front part of the mountingsection to the DIN rail.How to mount the amplifierԘԙPush the amplifier forward.Lift up the front part of the amplifier to remove it.Take care that if the front part is lifted without pushing theamplifier forward, the hook on the rear portion of the mounting section is likely to break.Note:How to remove the amplifierԙԘFiberlock leverFiberԚHow to connect the fiber cablesԘԙԚSnap the fiber lock lever down.Insert the fiber cables slowly into the inlets until theystop. (Note 1)Return the fiber lock lever to the original position, till itstops.Notes: 1)2)In case the fiber cables are not inserted to a position wherethey stop, the sensing range reduces. In case of a flexiblefiber, take care that it may bend inside the amplifier, duringinsertion.With the coaxial reflective type fiber, such as, FD-G4 or FD-FM2, insert the single-core fi-ber cable into the beam-emitting inlet and the multi-core fiber cable into the beam-receiv-ing inlet. If they are inserted in reverse, the sensing accuracy will deteriorate.Be sure to fit the attachment to the fibers first before inserting the fibers to theamplifier. For details, refer to the instruction manual enclosed with the fibers.Make sure that the power supply is off while wiring.I/O CIRCUIT DIAGRAMS4Notes: 1)2)The quick-connection sub cable does not have +V (brown) and 0V (blue).The power is supplied from the connector of the main cable.50mA max., if five, or more, the connector type amplifiers are connected in cascade.٨ NPN output type1 +V3 Output2 0VTerminal arrange-ment diagram of theconnector type123100mA max. (Note 2)Load(Brown) +V (Note 1)(Black) Output + 12 to 24V DCr10%-(Blue) 0V (Note 1)Users' circuitInternal circuitSensor circuitTerminal No. of connector type Cable type / Color code of quick-connection cable٨ PNP output type1 +V3 Output2 0VTerminal arrange-ment diagram of theconnector type123Load+ 12 to 24V DCr10%-100mA max. (Note 2)(Brown) +V (Note 1)(Black) Output(Blue) 0V (Note 1)Users' circuitInternal circuitSensor circuitTerminal No. of connector type Cable type / Color code of quick-connection cableSWITCHING OUTPUT OPERATION5٨ The operation selection switch can be used to display different output operations(L-ON / D-ON) on the digital display. Disappears automaticallyafter 2 seconds.Disappears automaticallyafter 2 seconds.THRESHOLD VALUE (SENSITIVITY) AD-JUSTMENT6Ԙ Check the incident light intensity [in the digitaldisplay (red)] when a sensing object is placedin the sensing position.ԙ Check the incident light intensity [in the digitaldisplay (red)] when the sensing object isremoved from the sensing position.Ԛ Turn the threshold value adjuster to thethreshold value [in the digital display (green)]that is the value in between Ԙ and ԙ. (Thethreshold value is automatically written to theEEPROM.)(Incident light intensity)(Incident light intensity)(Threshold value)Sensingobject٨ When the threshold value adjuster is turned clockwise, the threshold valueincreases. When the threshold value adjuster is turned counterclockwise, thethreshold value decreases.>If there is a sufficient level of margin in the incident light intensity, the stability indica-tor (green) will light up.(Threshold value)(Threshold value)Notes: 1)2)3)4)FX-412غ, with the sensitivity adjuster shaped so that it can be turned manually usingfingers, is also available. However, the cable type is not available for FX-412غ.50mA, the connector type five, or more, amplifiers are connected in cascade.When the power supply is switched on, the light emission timing is automatically set forinterference prevention.The cable for amplifier connection is not supplied as an accessory. Make sure to use theoptional quick-connection cables given below.Main cable (3-core): CN-73-C1 (cable length 1m), CN-73-C2 (cable length 2m)CN-73-C5 (cable length 5m)Sub cable (1-core) : CN-71-C1 (cable length 1m), CN-71-C2 (cable length 2m)CN-71-C5 (cable length 5m)CAUTIONS٨٨٨٨٨٨٨٨٨٨٨٨٨٨٨٨٨٨This product has been developed / produced for industrial use only.Take care that wrong wiring will damage the sensor.Make sure that the power supply is off while wiring.Verify that the supply voltage variation is within the rating.Take care that if a voltage exceeding the rated range is applied, or if an ACpower supply is directly connected, the sensor may get burnt or damaged.In case noise generating equipment (switching regulator, inverter motor, etc.) isused in the vicinity of this product, connect the frame ground (F.G.) terminal ofthe equipment to an actual ground.If power is supplied from a commercial switching regulator, ensure that the frameground (F.G.) terminal of the power supply is connected to an actual ground.Do not use during the initial transient time (0.5 sec.) after the power supply isswitched on.Take care that short-circuit of the load or wrong wiring may burn or damage the sensor.Do not run the wires together with high-voltage lines or power lines or put them inthe same raceway. This can cause malfunction due to induction.Extension up to total 100m (if 5 to 8 units are connected in cascade: 50m, if 9 to16 units are connected in cascade: 20m) is possible with 0.3mm2, or more, cable.However, in order to reduce noise, make the wiring as short as possible.Take care that cable extension increases the residual voltage.This sensor is suitable for indoor use only.Avoid dust, dirt, and steam.Take care that the product does not come in contact with water, oil, grease,organic solvents, such as, thinner, etc., strong acid or alkaline.This sensor cannot be used in an environment containing inflammable or explosive gases.Never disassemble or modify the sensor.The changes to the settings are written to the EEPROM, but because theEEPROM has a limited service life, you should avoid changing the settings anymore than 1 million times.12>>(Response timechange mode ) Standard Response time: 500Ǵs or lessResponse time: 4.5ms or lessLong-rangeResponse time: 150Ǵs or lessHigh speed( Emitting intensityselection mode )(Note 1)Emitting power HiEmitting power Lo(Timer settingmode )Without timerOFF-delayON-delayONE-SHOTThe timer period can be set within the following ranges:1 to 10 ms: 1 ms units; 10 to 100 ms: 10 ms units; 100 to 500 ms: 50 ms units500 to 1000 ms: 100 ms units; 1000 to 3000 ms: 500 ms unitsPress and hold for 2 seconds or more(Digital displayinversion mode )(Eco mode)Peak / Bottomhold mode(The actual display will be ' '.)(Peak value) (Bottom value)Note: This mode is not incorporatedin the blue LED type andgreen LED type.9When the setting switch is pressed and held for 10 sec., until ' ' is dis-played while in 'RUN' mode, the all settings are returned to the factory setting.(For the factory setting, refer to '٨Mode table' in ' MODE SELECTION'.)7FACTORY SETTING٨KEY LOCK FUNCTION8Note: Although the display changes to the indication of 'SET'condition 2 sec. after pressing the setting switch, keeppressing the switch. Furthermore, the sensor does not go into the key lock setting from 'SET' condition.Press and holdfor 5 sec. (Note)(Set to OFF)(Set to ON)٨٨When the setting switch is pressed andhold for 5 sec. while in 'RUN'mode, thekey lock function can be set / canceled.When the key lock function is set to ON,even if the threshold value adjuster or thesetting switch is operated, ' ' is displayedand the key operation cannot be carried out.For mounting and removing the amplifier, refer to ' MOUNTING'.2ԘԙԚԛMount the amplifiers, one by one,on the DIN rail.Slide the amplifiers next to eachother, and connect the quick-con-nection cables.Mount the optional end plates(MS-DIN-E) at both the ends tohold the amplifiers between theirflat sides.Tighten the screws to fix the endplates.ԘԙԚLoosen the screws of the end plates.Remove the end plates.Slide the amplifiers and removethem one by one.Cascading methodDismantlingMain cable (CN-73-Cغ)(optional)End plates (MS-DIN-E)(optional)End plates (MS-DIN-E)(optional)Sub cable (CN-71-Cغ)(optional)SlideSlideFX-411GP-C2FX-411P-C2PNP outputNPN output (Note 1)FX-411BP-C2FX-411P FX-411BP FX-411GPFX-411 FX-411B FX-411G FX-411B-C2FX-411-C2 FX-411G-C2ItemType Red LED Blue LED Green LED Red LED Blue LED Green LEDConnector type Cable typeFAST: 150Ǵs or less, STD: 500Ǵs or less, U-LG: 4.5ms or less selectable with switchLight-ON or Dark-ON, selectable with switchOutput operationIncorporatedShort-circuit protectionNormal operation: 960mW or less(Current consumption 40mA or less at 24V supply voltage)ECO mode: 840mW or less(Current consumption 35mA or less at 24V supply voltage)Normal operation: 720mW or less(Current consumption 30mA or less at 24V supply voltage)ECO mode: 580mW or less(Current consumption 24mA or less at 24V supply voltage)Response timeOutputNPN open-collector transistorMaximum sink current: 100mA (Note 2)Applied voltage: 30V DC or less(between output and 0V)Residual voltage: 1.5V or less[at 100mA (Note 2) sink current]PNP open-collector transistorMaximum source current: 100mA (Note 2 )Applied voltage: 30V DC or less(between output and +V)Residual voltage: 1.5V or less[at 100mA (Note 2) source current]Power consumption12 to 24V DCr10% Ripple P-P 10% or lessSupply voltageIncorporated [up to four fibers can be mounted adjacently (However,U-LG mode is eight fibers)Interference preventionfunctionCable35 to 85% RH, Storage: 35 to 85% RHAmbient temperature-10 to +55͠ (If 4 to 7 units are connected in cascade: -10 to +50͠ ,if 8 to 16 units are connected in cascade: -10 to +45͠)(No dew condensation or icing allowed), Storage: -20 to +70͠Peak emission wavelength 650nm 470nm 525nm 650nm 470nm 525nmEmitting elementAmbient humidity0.3mm2 3-core cabtyre cable, 2m long (Cable type only)20g approx. 60g approx.Enclosure: Heat-resistant ABS, Transparent cover: PolycarbonateSetting switch: Heat-resistant ABS, Threshold value adjuster: PolycarbonateMaterialWeightGreen LEDRed LED Blue LED Green LED Red LED Blue LEDModelNo.Thank you very much for purchasing Panasonic products. Please read this InstructionManual carefully and thoroughly for the correct and optimum use of this product.Kindly keep this manual in a convenient place for quick reference.INSTRUCTION MANUALDigital Fiber Sensor Amplifier FX-400 Series٨٨The models listed under “ SPECIFICATIONS” come with CE Marking.As for all other models, please contact our office.Contact for CEPanasonic Electric Works Europe AGRudolf-Diesel-Ring 2, D-83607 Holzkirchen, GermanyPanasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15, 22525 Hamburg,Germany11INTENDED PRODUCTS FOR CE MARKING13Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com |