Panasonic HL-C203F Instruction Manual
Also see for HL-C203F: User manualInstruction manual
INSTRUCTION MANUALUltra High-Speed, High-Accuracy Laser Displacement SensorSensor HeadHL-C203F(E), HL-C203F(E)-MKMJE-HLC203F(05) No.0041-43VThank you very much for purchasing Panasonic products. Read this Instruction Man-ual carefully and thoroughly for the correct and optimum use of this product. Kindlykeep this manual in a convenient place for quick reference.WARNING● This product is intended to detect the objects and does not have the control func-tion to ensure safety such as accident prevention.Do not use the product as a sensing device to protect human body.● Be careful not to directly watch or touch the direct laser beam or reflected laser beam.● The product was developed and manufactured for industrial use.BEFORE USE● Before using the product, check the sensor head model and contents of packing.● Sensor head modelCheck the model name of product at the top of sensor head.● PackingCheck that all of the following components are included in thepackage.• 1 sensor head unit• 1 Instruction manual• Laser warning labels[JIS/IEC: 1 set, GB: 1 set (E type only), FDA: 1 set]● This product satisfies the adaption of CE product by using in combination withcontroller and programmable display, which are subjected to CE. Please confirmthat there is CE mark on connecting controller’s label.● Contact for CEPanasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15, 22525 Hamburg,Germany1 DESCRIPTION● HL-C203F(E), HL-C203F(E)-MK displacement sensor head achieves ultra high-speedand high-accurate measurement using linear image sensor as light receiving elementto be used on equipment that require high-speed operation with high-accuracy.● The product is used at diffuse or specular reflection sensor head by installing and setting.2 CAUTIONS ON HANDLING LASER LIGHT● In order to prevent the accidents by laser product and protect the users, IEC, JIS,GB and FDA establish the following standards respectively.IEC : IEC 60825-1 -2007JIS : JIS C 6802 -2005GB : GB 7247.1 -2012FDA : PART 1040(PERFORMANCE STANDARDS FOR LIGHTEMITTING PRODUCTS)These standards classifies laser products according to the level of hazard and pro-vide the safety measures for respective classes (Refer to the “FDA Standard” table).● FDA standardRequirements Class *1I IIa II IIIa IIIb IVPerformance (all laser products)Protective housing [1040.10 (f) (1)]Safety interlock [1040.10 (f) (2)]Location of controls [1040.10 (f) (7)]Viewing optics [1040.10 (f) (8)]Scanning safeguard [1040.10 (f) (9)]R *2R *3,4N/ARRR *2R *3,4RRRR *2R *3,4RRRR *2R *3,4RRRR *2R *3,4RRRR *2R *3,4RRRPerformance (laser system)Remote control connector [1040.10 (f) (3)]Key control [1040.10 (f) (4)]Emission indicator [1040.10 (f) (5)]Beam attenuator [1040.10 (f) (6)]Reset [1040.10 (f) (10)]N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ARRN/AN/AN/ARRN/ARRR *10RN/ARRR *10RR *13Performance (specific-purpose products)Medical [1040.11 (a)]Measurement, leveling, alignment [1040.11 (b)]Demonstration [1040.11 (c)]SSSSSSSSSS *8SSS *8NPS *11S *8NPS *11Labeling (all laser products)Certification/identification [1010.2,3]Protective housing [1040.10 (g) (6),(7)]Aperture [1040.10 (g) (4)]Class warning [1040.10 (g) (1),(2),(3)]RD *5N/AN/ARR *5N/AR *6RR *5N/AR *7RR *5N/AR *9RR *5N/AR *12RR *5N/AR *12Information (all laser products)User information [1040.10 (h) (1)]Product literature [1040.10 (h) (2) (i)]Service information [1040.10 (h) (2) (ii)]RN/ARRRRRRRRRRRRRRRRR : RequiredN/A : Not applicableS : Same as for other products of that Class. Also see footnotes.NP : Not permittedD : Depends on level of inner radiation*1 : Class is based on the maximum level of laser exposure during operation.*2 : Required wherever and whenever human access to laser radiation above Class I limits is notneeded for product to perform its functions.*3 : Required for protective housings opened during operation or maintenance, if human accessthus gained is not always necessary when housing is opened.*4 : The requirements for interlock differ depending on the class of inner radiation.*5 : The contents of label differ depending on the level and wavelength of laser radiation inside theprotective housing.*6 : Warning statement label*7 : CAUTION logotype*8 : The method to measure the level of laser radiation to human body is required.*9 : CAUTION if 2.5mWcm-2 or less, DANGER is greater than 2.5mWcm -2 .*10 : Time difference is needed between instruction and emission.*12 : DANGER logotype*13 : Required after August 20, 1986.● Warning / Aperture label● Certification / Identification label● WARNING labelIn ChineseIn Japanese / English / Korean (E type only)● Install the product so the laser beam comes higher or lower than eye level in or-der not to watch the beam directly during operation.Laser safety distance (Nominal Ocular Hazard Distance: NOHD) is approx. 0.4m. Thelaser beam must be terminated at the end of its path by a diffuse reflector or an absorber.● Please contact our company if the system breaks down. It is not equipped with a func-tion that stops laser radiation automatically during disassembling the sensor head.The users therefore may be exposed to laser beam in disassembling the sensor head.● Do not use the system in the manner other than specified in this Instruction Manual.3 EXPORT REGULATIONS BY JAPANESE GOVERNMENT● HL-C203F and HL-C203F-MK are subject to export control regulation by the For-eign Exchange and Foreign Trade Law. Export admission by Japanese govern-ment is required before the product is to be exported or brought out of the country.These products are also subject to Article 1.B.3.b.1 of Nuclear Suppliers Group ininternational export control regime and 2.B.6.b.1 of Wassenaar Arrangement.● Please follow the export control regulations required.HL-C203FE and HL-C203FE-MK (E type) are not subject to export control regula-tions under the condition that they are used combined with the non-pertinent con-troller to export control specified by Foreign Exchange and Foreign Trade Law.When they are combined with the pertinent controller to export control, they aresubject to the Law. In this case export admission by Japanese government is re-quired before the product is to be exported or brought out of the country.4 SPECIFICATIONSModel No. HL-C203F(E) HL-C203F(E)-MKDiffuse Reflection Specular Reflection Diffuse Reflection Specular ReflectionMeas. method (Note 2) Diffuse reflection / Specular reflectionMeasurement center distance 30mm 26.4mm 30mm 26.4mmMeasurement range (Note 3) ±5mm ±4.6mm ±5mm ±4.6mmBeam source Red semiconductor laser Class II (FDA), Class 2 (JIS/IEC/GB)Max output: 1mW, Emission Peak wavelength: 658nmBeam diameter (Note 4) Approx. ø30μm Approx. 30 × 1,200μmBeam receiving element Linear image sensorResolution 0.1μm / average times: 256, 0.025μm /average times: 4,096[E type (Note 5) 0.25μm / average times 256]Linearity ±0.03%F.S.Temperature characteristics 0.01%F.S./°CIndicatorLaser emission Green LED: Lights up during laser emission.Meas. range Yellow LED: Near measurement center:ON, within measurement range:Blink, beyond the range:OFFProtective structure IP67 (except connector)Pollution degree 2Insulation resistance 20M ohms or more by 500V DC megger (between all the terminals and enclosure.)DielectricwithstandCommercial Frequency AC 500V for 1min. (between all the terminals and enclosure.)Impulse ±1,000V 1.2/50μs (between all the terminals and enclosure.)Vibration resistance Endurance: 10 to 55Hz (cycle: 1minute), Resistant amplitude of vibration: 1.5mm, inX, Y, and Z directions for 2 hoursShock resistance 196m/ s 2 in X, Y, and Z directions for 3 timesAmbient illuminance (Note 6) 3,000ℓx or less (illuinance at beam receiving surface using incandescent lamp)Ambient temperature 0 to +45°C (No dew condensation or icing allowed), At storage: -20 to +70°CAmbient humidity 35 to 85%RH At storage:35 to 85%RHAmbient Height 2,000m or lessMaterial Main unit case / cover faluminum: Die-cast, Front cover: GlassCable length 0.5mCable extension Extendible to 30m long maximum using the optional extension cable.Weight Approx. 250g including cable weightApplicable standards Conformed to EMC DirectiveNotes: 1) Measuring conditions are as follows unless otherwise specified; connection with controller, power voltage:24V DC, ambient temperature: 20°C, sampling cycle: 40μs, average times:256, at measurement center dis-tance, object substance: white ceramic,, and digital measurement value.2) Use the external ND filter (optional) in case the amount of reflected beam is too large on Specular Reflection installation.3) The measurement range is limites between +0.0 and +5.0mm (in case the sampling cycle is 20μs at diffuse reflection), between+0.0 and +4.6mm (in case the sampling cycle is 20μs at specular reflection), between +3.8 and +5.0mm (in case the samplingcycle is 10μs at diffuse reflection), or between +3.6 and +4.6mm (in case the sampling cycle is 10μs at specular reflection).4) The figure shows the value at measurement center distance. It is determined by 1/e2 (approximately 13.5%)of center beam intensity. Due to leak light outside the specified area, the reflectance around the detectingpoint may be higher than at the point and this may affect the measurement value.5) The minimum resolution of 0.25μm can be achieved if the sensor head is connected to the controller that isnot subject to “Foreign Exchange and Foreign Trade Law”.6) The variation in ambient illuminance is ±0.03%F.S. or less. |
Related manuals for Panasonic HL-C203F
Panasonic HL-C203F-MK Instruction Manual
Panasonic HL-C203B Instruction Manual
Panasonic HL-C201F Instruction Manual
Panasonic HL-C201A Instruction Manual
Panasonic HL-C211F Instruction Manual
Panasonic HL-C211F5 Instruction Manual
Panasonic HL-C235BE Instruction Manual
Panasonic HL-C211BE Instruction Manual
Panasonic HL-C201A-SP3 Instruction Manual
Panasonic HL-C211F-MK Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine