Panasonic KW9M Eco-Power Meter Installation Instructions Manual
Also see for KW9M Eco-Power Meter: User manualUser manualUser manual
Press during each item is displayed to change the setting value.Press to display the confirmation window.Select [YES] and press to decide the setting value.However no value is changed, the confirmation window is skipped andit displays the measuring value display.*3 It skips when [30] is set at pulse input 1.*1 It skips when [Peak] or [30min] is set atpower demand type.*2 It skips when except [30min] is set atpower demand type.*4 It skips when [Clock] is selected atpulse input 1.*5 It skips when [0] is set at auto-displaysetting.*6 It skips when [YES] is selected at resetall integral value.*7 It skips when [OFF] is selected atthe previous program.Measuring value displayEnter passwordPhase/Wire Power demand typePower demandinterval *1Power demandinterval 2 *1Power input type *2Pulse type *2Pulse rate (elecric powerconvertion) *2Pulse constant value *2Current demand intervalCalcuration methodfor 30-min demand *2CT typePrimary sidecurrent of CTRated voltageVT ratioOver voltageProtocolDevice numberTransmissionspeedTransmissionformatStop bitResponse timeAuto-offLuminanceAlarm blinkingUpdate cycleAuto-displayDisplay cycle*5TemperaturecorrectionReset allintegral valueCalendartimerPasswordsettingSetting ModeUnder voltageOver currentUnder current【Powermeasurement】 【Pulse】【Demand】 【Communication】 【Optional function】 【Time program】 【Calendar timer】 【Password】Confirmation ModeMeasuring value displaySetting confirmationNOSetting confirmationYES10. Setting Flow11. How to Set the Parameters related toPower MeasurementSet before measuring.◆Phase / Wire◆Rated voltage ◆Conversion rate (P)◆Conversion rate (-P)◆Calender timer◆VT ratio◆Over Voltage/ Over Voltage 2◆Under Voltage / Under Voltage 2◆Over Current /Over Current 2◆Under Current /Under Current 2◆CT type◆Primary side current of CTSelect measured phase and wire system.◆How to Enter Password◆How to Initialize PasswordIt is necessary to enter password to shift to settingmode. Enter [0000] and shift to password settingmode when you set password at the first time.*When setting password, be careful for handling and note it.Measuring value displayMeasuring value displayPasswordentry windowPasswordentry windowPasswordinitialize windowSettingmode ofpowermeasurementWhen you forget the password, initialize it in thefollowing procedures. (Initial: [0000])It is impossible to decode the set password.IncreaseShift entered digit to the rightEnter passwordfrom left to rightIf the password is wrong,[FAIL] is displayed and it returnsto the password entry window.*If you make wrong password5 times, you can’t set 1-hour after.30 sec.Return to the measuring value displayInitialize[YES] Not initialize[NO]To use CT with secondary side current 5A: [5] (initial)To use CT with secondary side current 1A: [1]When the system is not matched with the measure system,it doesn’t measure correctlySelect using CT type (secondary side current).Set the primary side current of using CT.Enter the primary side current of CT that is set at CT typesetting.IncreaseDecrease[Set range] 1 to 65535 (initial: 5)Primary side current of using CT is 400A: [400]Set the rated voltage of measured voltage.Select the voltage input method, input voltage directlyor uses a voltage transformer (VT: secondary side rating110V) and set VT ratio.IncreaseDecrease IncreaseDecreaseIncreaseDecrease[Set range] 100 to 500 (initial:100)IncreaseDecrease[Set range] 0.00 to 99.99 /1kWh(initial:10.00)IncreaseDecrease[Set range] 0.00 to 99.99 /1kWh(initial:10.00)IncreaseDecrease[Set range]Jan. 1st, 2000 00:00: toDec. 31st, 2099 23:59[Set range] 1.00 to 600.00 (initial:1.00)IncreaseDecrease[Set range] 100.0 to 120.0 %(initial:105.0)IncreaseDecrease[Set range] 100.0 to 120.0 %(initial:105.0)IncreaseDecrease[Set range] 0.0 to 100.0 %(initial:0.0)IncreaseDecrease[Set range] 0.0 to 100.0 %(initial:0.0)IncreaseDecrease[Set range] 5.0 to 100.0 %(initial: 95.0)[Set range] 5.0 to 100.0 %(initial: 95.0)IncreaseDecrease[Set range] 0.1 to 120.0 %(initial: 100.0)IncreaseDecrease[Set range] 0.1 to 120.0 %(initial: 100.0)Set the ratio for the rated voltage to judge to be over voltageat [over volt] window.Set the ratio for the rated current to judge to be under currentat [under curr] window.Press , and [over volt 2] is displayed.At this window, set a ratio of voltage to clear overt voltage.Press , and [under curr 2] is displayed.At this window, set a ratio of current to clear under current.Press , and [under volt 2] is displayed.At this window, set a ratio of voltage to clear under voltage.Press , and [under curr 2] is displayed.At this window, set a ratio of voltage to clear under voltage.Set the ratio for the rated voltage to judge to be undervoltage at [under volt] window.Set the ratio for the rated voltage to judge to be overcurrent at [over curr] window.Input directly without VT: [1.00]Use VT : [1.01 to 600.00]Set the conversion rate per integral active power 1 kWh.You can set 5 kinds of rate for each time zone, all-time,time zone 1, time zone 2, time zone 3 and time zone 4.Rate for all-time is used when time program is not set.When you set one or more time programs, the rates fortime zone 1, 2, 3 and 4 are used. Rate for all-time is not used.Set the conversion rate per integral export power (-P) 1 kWh.Set the date and time.In order to use the logging function, set the date and time.・Refer to User’s manual for the other settings.Time zoneNone: all-timeT1: time zone 1 T2: time zone 2T3: time zone 3 T4: time zone 4Time zoneNone: all-timeT1: time zone 1 T2: time zone 2T3: time zone 3 T4: time zone 4Single-phase 2-wire (initial) Single-phase 3-wireThree-phase 4-wire Three-phase 3-wireRate(P)Total, T1-4Rate(-P)Total, T1-4Pulse input 1Clocksynchronize *3Pulse input 2Prescale 1 *4Pulse output 1Pulse output 2Prescale 2*7Program 7*7Program 8*7Program 9*7Program 10Program 1*7Program 2*7Program 3*7Program 4*7Program 5*7Program 6Select setting item with and pressand the value will be blinking.Set with andWhen you select [YES] with the confirmation windowand press , the setting values are decided.Reset integralvalue 1 *6VersionReset countvalue 1 *6Reset countvalue 2 *6Reset loggingdata *6Reset integralvalue 2 *6Reset integralvalue 3 *6Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com |
Related manuals for Panasonic KW9M Eco-Power Meter
Panasonic KW2M Installation Instructions Manual
Panasonic MKG1500-DE Installation Instructions Manual
Panasonic KW1M Eco-Power METER User Manual
Panasonic KW2G Eco-POWER METER User Manual
Panasonic NA1-11 Instruction Manual
Panasonic EYFR02 Operating Instructions Manual
Panasonic Eco-POWER KW7M User Manual
Panasonic DMR-E20 Operating Instructions Manual
Panasonic WJ-NX100/2E Installation Manual
Panasonic FM-252-4(-P) Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine