7.1.5 Restarting the PBXIf the PBX does not operate properly, restart the PBX using Web Maintenance Console. Before restarting thePBX, try the system feature again to confirm whether there definitely is a problem or not.Note• When the System Mode Switch is set to "NORMAL", restarting the PBX causes the following:– Camp-on is cleared.– Calls on hold are terminated.– Calls on exclusive hold are terminated.– Calls in progress are terminated.– Call park is cleared.Other data stored in memory, except the above, are not cleared.• Be aware that restarting the PBX with the System Mode Switch in the "SYSTEM INITIALIZE" positionclears all data stored in the PBX. Do not perform this operation unless you intend to delete all datafrom the PBX.• When the PBX is set to obtain IP addressing information automatically, and the PBX is not able toobtain appropriate IP addressing information from an external DHCP server, the PBX starts up with itsdefault IP addresses and the STATUS indicator on the front of the cabinet turns red. For the default IPaddresses, refer to "5.3 Starting Web Maintenance Console".OperationIf the PBX does not operate properly:1. Slide the System Mode Switch to the "NORMAL" position.System Mode Switch2. Start the Web Maintenance Console.3. Log in using the Installer level account.4. On the Home screen, click Maintenance ® System Control ® System Reset ® System Reset.5. Follow the prompts.Restarting the PBX will start.Note• When the power switch is turned on, or when the PBX recovers from a power failure, the PBX willrestart. The time required to restart depends on the number of connected extensions.296 Installation Manual7.1.5 Restarting the PBX