5.2 Wireless System Installation154 DECT Installation6. Wireless Extension ConnectionUse a Cell Station Cord (4-conductor wiring - included) and 4-pin plug (included) toconnect the cell station line. There are 2 plugs for the KX-TD144 and 6 plugs for the KX-TD146 to connect the Cell Stations.Maximum length of the cable: AWG 24 (0.6 mm in diameter): Under 1 kma) Insert the wires of the 4-conductor wiring cord into the holes in the plug to connect pins"D1", "D2", "V1" and "V2".D1: Data 1 V1: Voltage +D2: Data 2 V2: Voltage –Press the transparent part into the black part.Insert the other end of the wires into the modular plug.NoteDo not peel off the wire coating. Insert the wires all the way.b) Insert the 4-pin plug into a cell station jack on the unit, and attach the ferrite core(included) to the plug cord.D1V1V2D2D1V1V2D2124-pin plug Modular plugPanasonic61CSno.D1V1V2D22345CS INF DIGITAL SUPER HYBRID SYSTEM6CSPanasonicCS INF21CSno. D1V1V2D2DECT5 cmTo the Cell Station To the Cell StationFerrite CoreRoll the cord once aroundthe ferrite core and closethe core.Note: Put it in the cabinetwhen closing the cabinet cover.Connect the ground terminal to ground.Note: If other expansion units areinstalled, the frame ground connectionis required for only one unit.KX-TD144 KX-TD146