41KX-TG1711MEB/KX-TG1712MEB/KX-TGA171MEB11.6. Things to Do after Replacing ICCautions:Since this page is common to each country, it may not apply to some models in your country. The contents below are theminimum adjustments required for operation.11.6.1. Base UnitBefore doing the following adjustment, be sure to do PC Setting (P.34) in The Setting Method of JIG (Base Unit).Note:(*1) Refer to Check Point (Base Unit) (P.24)(*2) xx: country code, yyy: revision number“xx” and “yyy” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC(P.34).11.6.2. HandsetBefore doing the following adjustment, be sure to do PC Setting (P.38) in The Setting Method of JIG (Handset).Note:(*3) Refer to Check Point (Handset) (P.27)(*4) xx: country code, yyy: revision number“xx” and “yyy” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC(P.38).IC Necessary AdjustmentBBIC Programs for Voice processing, interface for RF andEEPROM1. Clock adjustment: Refer to Check Point (D). (*1)EEPROM Adjustment parameter data(country version batch file, default batch file, etc.)1. Default batch file: Execute the command “DefaultEEP”.2. Country version batch file: Execute the command“TG16XX_FP_ROM2_xx_yyy.bat”. (*2)3. Clock adjustment: Refer to Check Point (D). (*1)IC Necessary AdjustmentBBIC Programs for Voice processing, interface for RFand EEPROM1. Clock adjustment: Refer to Check Point (H). (*3)2. 4.0 V setting and battery low detection: Refer to Check Point (A),(F) and (G). (*3)EEPROM Adjustment parameter data(country version batch file, default batch file, etc.)1. Default batch file: Execute the command “Default”.2. Melody Initialize batch file; Execute the Command "Melody_008".3. Country version batch file: Execute the command"TG16XX_PP_xx_yyy.bat".4. Clock adjustment: Refer to Check Point (H). (*3)5. 4.0 V setting and battery low detection: Refer to Check Point (A),(F) and (G). (*3)