- 11 -- 10 -Wiring Maintenance/inspections/ How to reset a trip• GP seriesConnector on amplifier side: Parts No. S10B-PASK-2 (J.S.TMfg.,Co.,Ltd.) or equivalent.mating connector: Representative Housing PAP-10V-S,( Terminal SPHD-001T-P0.5 or SPHD-002T-P0.5 )Terminalnumber Terminalsymbol Terminalname Default Terminal explanation functionselection logicselection1 I 1*1 Signalinput 1 Run start In turning on signal, short between “ I 1”and “GND”. *2 Pr50 Pr542 I 2*1 Signalinput 2PointdesignationIn turning on signal, short between “ I 2”and “GND”. *2 Pr51 Pr553 I 3*1 Signalinput 3HomesensorIn turning on signal, short between “ I 3”and “GND”. *2 Pr52 Pr564 (NC) — — Do not connect anything. — —5 I 4*1 Signalinput 4ForcedtripIn turning on signal, short between “ I 4”and “GND”. *2 Pr53 Pr576 GND Controlground — Common ground terminal for controlsignal. — —7 (NC) — — Do not connect anything. — —8 +5V Powersupply — Set 50 mA or below — —9 01 *1 Signaloutput 1 Trip outputOpen collector output.Open collector Vce max: DC30 V,Ic max: 50 mAPr5C Pr5E10 02 *1 Signaloutput 2In-motionsignalOpen collector output.Open collector Vce max; DC 30 V,Ic max; 50 mAPr5d Pr5F*1 Function of input/output can be changed by PANATERM for BL and the Digital key pad.Default is shown.*2 Maximum rated voltage: –0.5 to 5.5V.• Connector for control signals pin number is 1, 2, ... 10 in the order from grounding terminal side.• Permissible length for control signal cable is 5m or less.Connector for comunications (SER)Modular jack: 85503-0001 (Japan Molex Inc.) or equivalent (RJ45)Terminalnumber TerminalSymbol Terminal explanation • Connection of digital key pad ofan option is possible. digital keypad connecting cable of an option(DV0P383**) is required.• The terminal number of a modularjack is the followingfigure• Refer to operation manual(Overall) for the correspondenceprocedure of RS485.1 — Do not connect anything.2 +5 V DC5 V power supply for digital key pad3 SOT Interface for digital key pad orPANATERM for BL4 SIN5 RS485+ for connect RS485+6 RS485− for connest RS485–7 GND power supply GNG for Digital key pad8 SCK Interface for digital key padMaintenance/ inspectionsRoutine maintenance and inspection are essential for proper and satisfactory operation ofthe motor.Maintenance/ Inspection itemMaintenance/Check itemInspectionprocedure ConditionInput voltage Voltmeter Must be within ±10% of rating.Input current Ammeter Must be within rated input current described on nameplate.InsulationresistanceInsulationresistancetesterMeasure the insulation resistance with 500 V Megger. It must beabove 1 MΩ.Measuring position: Between power input line (L1, L2,L3) andgrounding wireNoise Hearing Noise level must not be different from the usual level. In addition,abnormal noise such as rumbling noise must not be heard.Vibration By hand Free from abnormal vibration.InstallationboltTorquewrench Check for loosening of bolt, and tighten additionally as necessary.Useenvironment By sightCheck the ambient temperature and humidity, and make sure thatdirt, dust, or foreign substance is not found.check the waste thread etc don’t attached to the windhole of brushlessamplifier.Caution• Power-on/off operations should be done by the operators themselves for ensuring safetyin checking.• Do not touch the motor while it is running or immediately after it stops because it gets hotand stays hot for a while after power has been turned off.• The DC500 V megger testing should be performed only on the main circuit. Be sure todisconnect the power supply. Otherwise, failure will occur. The resistance should be 1MΩ between the ground with L1, L2 and L3 short-circuited.When disassembly, troubleshooting, etc., is needed,be sure to contact our service department or the sales agent of purchase.How to clear tripIf the motor trips (alarm LED is lit), remove the cause and use one of the following clearingprocedures.• Turn off power, and when the power LED goes off, turn on power again.• For clearing procedure using the panel B or an input terminal, refer to the InstructionManual (Overall).Before clearing the trip, be sure to locate and remove the cause.