24 25Test runInspection prior to test run/Test runInspection prior to test runAfter completion of installation and wiring, check the connections and supplies as shownbelow:(1) Make sure that all wiring is correct.• Power input terminal: Check of connection L1, L2, L3• Check of connection of a motor connector(2) Make sure that input power supply conforms to rating.Test runYou can operate according to one of the following methods 1 , 2 , 3 , 4 .1 When operating with switches and knobs on the front of the product(Factory setting)Power LEDRotate direction selector switch(CW/CCW)Alarm LEDSpeed setting KnobRUN switch (RUN/STANDBY)When power is turned on, the power LED will light green.When a trip occurs, the alarm LED lights in red. When the RUN switch is set to the RUNside, the motor rotates and when it is returned to the STANDBY side it stops.The rotation direction can be changed with the rotate direction selector switch. If thisswitch is changed while the motor is rotating, a trip may occur depending on the inertia ofthe load.The rotation speed can be adjusted with the speed setting knob.If you stop for a long time, please turn off the power.■ AttentionIf you turn off the power with the RUN switch on the RUN side, it is dangerousbecause the motor restarts when the power is turned on. Before turning on thepower, make sure that it is on the STANDBY side.• When gear head is incorporated, the rotation direction of motor and that of gearoutput shaft are reversed for some gear reduction ratio. Please refer to the table of thepermissible torque (P.28).2 Operation with external control signalSet the RUN switch on the front panel to “RUN”, therotate direction selector switch to “CCW”, and the I1input enable switch (SW3) on the back of the prod-uct to “ON”.When power is turned on, the power LED lights ingreen.Upon tripping, the alarm LED lights in red.The motor runs at the speed set with the speedsetting knob when the Run command input “ I 1” isshort-circuited to “COM” and stops when the circuitbetween “ I 1” and “COM” is disconnected.Rotating direction: CW when the Rotation changeover input “ I 2” is shorted to “COM”,and CCW when “ I 2” is disconnected from “COM”.CW : clockwise when viewed from motor shaftCCW : counterclockwise when viewed from motor shaftIf the rotation direction is reversed while the motor is running, the rapid directionalswitching can cause tripping due to the inertia of load.When using a relay or switch for short-circuiting, select a minute electric current type(minimum guaranteed current 1 mA or below).■ AttentionWhen power is turned off and on again while RUN command input “ I 1” isshort-circuited to “COM”, the motor will start again, which is dangerous. Makesure that the circuit between “ I 1” and “COM” is open before turning on power.• When gear head is incorporated, the rotation direction of motor and that of gearoutput shaft are reversed for some gear reduction ratio. Please refer to the table of thepermissible torque (P.28).02Change ofdirection10101+5VFINCOMI3I4I5I2I1Runcommand