Contents - microwave oven
- Table Of Contents
- SCHEMATIC DIAGRAM
- DESCRIPTION OF OPERATING SEQUENCE
- Sensor reheat (Only for sensor models)
- CAUTIONS TO BE OBSERVED WHEN TROUBLESHOOTING
- Part replacement
- DISASSEMBLY AND PARTS REPLACEMENT PROCEDURE
- Fan motor
- Turntable motor
- Inverter power supply
- COMPONENT TEST PROCEDURE
- Inverter power supply (U)
- MEASUREMENTS AND ADJUSTMENTS
- PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE
- TROUBLESHOOTING GUIDE
- Troubleshooting of inverter circuit (U) and magnetron NEW H.V
- Simple way of H.V. Inverter/magnetron troubleshooting
- EXPLODED VIEW AND PARTS LIST
- PARTS LIST
- DOOR ASSEMBLY
- ESCUTCHEON BASE ASSEMBLY
- PACKING AND ACCESSORIES
- WIRING MATERIALS
- DIGITAL PROGRAMMER CIRCUIT
- NN-T685SF APH/CPH, T675SF APH
- NN-T665SF APH, T655SF APH, T664SFR APH
- NN-H665 APH/CPH, H635 APH, S655 APH, S645 APH S615 CPH
- S605 CPH, S505 APH/CPH, S655 RPH, S645 RPH H624*FR APH, H504*FR APH
|
CAUTION NEW. H.V.1. High voltage is present at the high voltage terminal of the HighVoltage Inverter (U) including aluminum heat sink during any cookcycle.2. It is neither necessary nor advisable to attempt measurement of thehigh voltage.3. Before touching any oven components, or wiring, always unplugthe oven from its power source and discharge the high voltagecapacitors.5.1. Primary latch switch (doorswitch and power relay B)interlocks.1. Unplug lead connectors to Power Relay B and verify opencircuit of the power relay B 1-2terminals.2. Unplug lead connectors to Primary Latch Switch and DoorSwitch.3. Test the continuity of switches at door opened and closedpositions with ohm meter (low scale).Normal continuity readings should be as follows.Door Closed Door OpenedPrimary Latch switch 0Ω (Close) Ω(Open)Door Switch 0Ω (Close) Ω(Open)Power Relay B Ω (Close) Ω(Open)5.2. Short switch & monitor1. Unplug lead wires from Inverter Power Supply (U) primaryterminals.2. Connect test probes of ohm meter to the disconnectedleads which were connected to Inverter Power Supply (U).3. Test the continuity of short switch with door opened andclosed positions using lowest scale of the ohm meter.Normal continuity readings should be as follows.Door Opened Door Closed0Ω Ω5.3. MagnetronContinuity checks can only indicate an open filament or ashorted magnetron. To diagnose for an open filament orshorted magnetron.1. Isolate magnetron from the circuit by disconnecting theleads.2. A continuity check across magnetron filament terminalsshould indicate one ohm or less.3. A continuity check between each filament terminal andmagnetron case should read open.5.4. Membrane key board(Membrane switch assembly)Check continuity between switch terminals, by tapping anappropriate pad on the key board. The contacts assignment ofthe respective pads on the key board is as shown in digitalprogrammer circuit. (Refer to Mini Manual)5 COMPONENT TEST PROCEDURE16NN-T695 NN-T685SF PreviousNext |