6 Service Mode6.1. Error Display"PUSH THE RESET SWITCH" is displayed automatically on the EVF or the LCD Monitor when an undesirable condition hasoccurred.Fig. 1Note:When "PUSH THE RESET SWITCH" is displayed repeatedly, service is required. Check the Error Code which is listed in theService Menu.6.2. Service MenuWhen abnormal detection contents are confirmed, do the following operation. Automatic diagnosis code will bedisplayed. (ServiceMenu)To enter the Service MenuPush the [PHOTO SHOT], [JOYSTICK CONTROL LEFT] and [RECORDING START/STOP] simultaneously for 3 seconds (withno SD Card inserted).Note:If a Disc or SD Card is inserted, the above operation will not work.This operation displays the following Service Menu items.To select the Item1. Set to Service Menu.2. Press the [JOYSTICK CONTROL UP/DOWN] to select item [3].3. Press the [JOYSTICK CONTROL RIGHT] to display [YES/NO] screen.4. Press the [JOYSTICK CONTROL UP/DOWN] to select [YES].5. Press the [JOYSTICK CONTROL CENTER].Note:Only perform items 3 in the Service Menu.To exit the Service MenuUnplug the AC Cord.22NV-GS24EG NV-GS26GK / NV-GS27E NV-GS27EB / NV-GS27EE NV-GS27EF / NV-GS27EG NV-GS27EP / NV-GS27GC NV-GS27GN / NV-GS37E NV-GS37EB / NV-GS37EG NV-GS37EK / NV-GS37EP NV-GS47/ NV-GS47GC NV-GS57EE / NV-GS57GC NV-GS58GK