24Control commands via LANWhen WEB Control administrator rights password is set (Protect mode)Connection methodObtain the IP address and port number (Initial set value = 1024) of the projector and1)make a request for connection to the projector.Acquire the IP address from the menu screen of the projector, and the port number from the WEB controlpage.IP address : Obtain from MAIN MENU → [Network] → [Network status]Port No. : Acquire from the WEB control “Detailed set up” → “Command port setting” pageThere is a response from the projector.2)Response dataData section Blank Mode Blank Random numbersectionTerminationsymbol“NTCONTROL”(ASCII string)‘ ’0x20‘1’0x31‘ ’0x20“zzzzzzzz”(ASCII code hexadecimalnumber)(CR)0x0d9 bytes 1 byte 1 byte 1 byte 8 bytes 1 byteMode : 1 = Protect modeGenerate a 32-byte hash value from the following data using MD5 algorithm.3)“xxxxxx:yyyyy:zzzzzzzz”xxxxxx : Administrator rights user name for WEB CONTROL (Default user name is “admin1”)yyyyy : Password of above administrator rights user (Default password is “panasonic”)zzzzzzzz : 8-byte random number obtained in Step 2Command transmission methodTransmit using the following command format.Transmitted dataHeader Data section Termination symbolHash value(See above)‘0’0x30‘0’0x30Control command(ASCII string)(CR)0x0d32 bytes 1 byte 1 byte Undefined length 1 byteReceive dataHeader Data section Termination symbol‘0’0x30‘0’0x30Control command(ASCII string)(CR)0x0d1 byte 1 byte Undefined length 1 byteError responseError message Termination symbol“ERR1”“ERR2”“ERR3”“ERR4”“ERR5”“ERRA”Undefined control commandOut of parameter rangeBusy state or no-acceptable periodTimeout or no-acceptable periodWrong data lengthPassword mismatch(CR)0x0d4 bytes 1 byte