according to connected equipment. In this case, set HPLL to OFF.· EMULATESwitching the operation of RS-232C command to communicate with models other than F100 series.−−−− DEFAULT: F100/F100NT standard, D3500−−−− TYPE1: L730/L780/L735/LB/LC series−−−− TYPE2: L785−−−− OTHER: Models other than the above-mentioned (Consult your dealer or Authorized Service Center for details.)· AUDIO IN STANDBYSetting the audio output when STANDBY−−−− OFF: Does not output it.−−−− ON: Outputs it.Note:−−−− When setting it to "ON", audio source of the input channel when the power supply is turned off (switched to STANDBY)is outputted. Do with the remote control unit, control panel or RS-232C communication when you switch the channel.The audio volume can be adjusted by the remote control unit or RS-232C communication.· OVER SCANSetting the rate of over scanning−−−− 1: Approx. 6%−−−− 2: Approx. 4%Note:−−−− Normally, set it to "1".· MENU LOCKSwitching ON/OFF "MENU LOCK" function−−−− OFF: Accessible to MENU−−−− ON: The access to MENU is restricted (The password is required).−−−− When MENU LOCK is set to "ON", the password input screen is displayed when it accesses the menu, and theadjustment in the menu item is locked.· MENU LOCK PASSW ORDSetting the password into MENU LOCK−−−− The default password is "AAAA".When you want to reset the password into the default password, do the following operation.1. Press on the remote control unit the AUTO SETUP button, or on the main unit the INPUT SELECT button and thebutton at the same time for 2 seconds or more.2. Press button for 2 seconds or more.· ARF ROLLRolling the ARF (Auto Rolling Filter) compulsorily.· SELF CHECKTo enter the self-check mode· TEST PATTERNTo display test patterns· FLICKER ADJUSTTo enter the flicker adjustment mode2.3. Canceling EXT OPTIONPress "MENU" button on the main unit or remote control unit.3 Self-Check ModeThis mode is used to narrow down the location of the failure.3.1. Procedure to enter the self-check modeSelect "SELF CHECK" on "EXT OPTION" menu and press "ENTER" button on the main unit or remote control unit.7PT-F100NTU / PT-F100NTE / PT-F100NTEA / PT-F100U / PT-F100E / PT-F100EA