RXQ5~10M9W1B + RXYQ5~16M9W1B + REYQ8~16M8W1B(A) +RXYSQ4~6M7V3BVRVII and VRVII-S system air conditioner4PW35761-1AOperation manual69. MAINTENANCE9.1. Maintenance after a long stop period (eg. at thebeginning of the season)■ Check and remove everything that might be blocking inlet andoutlet vents of indoor units and outdoor units.■ Clean air filters and casings of indoor units. Refer to theoperation manual supplied with the indoor units for details onhow to proceed and make sure to install cleaned air filters backin the same position.■ Turn on the power at least 6 hours before operating the unit inorder to ensure smoother operation. As soon as the power isturned on, the remote controller displays appear.9.2. Maintenance before a long stop period (eg. at theend of the season)■ Let the indoor units run in fan only operation for about half a dayin order to dry the interior of the units. Refer to "7.1. Cooling,heating, fan only, and automatic operation" on page 3 for detailson fan only operation.■ Turn off the power. The remote controller displays disappear.■ Clean air filters and casings of indoor units. Refer to theoperation manual supplied with the indoor units for details onhow to proceed and make sure to install cleaned air filters backin the same position.10. FOLLOWING SYMPTOMS ARE NOT AIRCONDITIONER TROUBLESSymptom 1: The system does not operate■ The air conditioner does not start immediately after the ON/OFFbutton on the remote controller is pushed.If the operation lamp lights, the system is in normal condition.To prevent overloading of the compressor motor, the airconditioner starts 5 minutes after it is turned ON again in case itwas turned OFF just before. The same starting delay occursafter the operation mode selector button was used.■ If "Centralized Control" is displayed on the remote control andpressing the operation button causes the display to blink for afew seconds.This indicates that the central device is controlling the unit.The blinking display indicates that the remote control cannot beused.■ The system does not start immediately after the power supply isturned on.Wait one minute until the micro computer is prepared foroperation.Symptom 2: Cool/Heat cannot be changed over■ When the display shows " " (change-over undercentralized control), it shows that this is a slave remotecontroller.■ When the cool/heat changeover remote control switch isinstalled and the display shows " " (change-over undercentralized control).This is because cool/heat changeover is controlled by the cool/heat changeover remote control switch. Ask your dealer wherethe remote control switch is installed.Symptom 3: Fan operation is possible, but cooling and heating do notwork.■ Immediately after the power is turned on.The micro computer is getting ready to operate. Wait 10minutes.Symptom 4: The fan strength does not correspond to the setting.■ The fan strength does no change even if the fan strengthadjustment button in pressed.During heating operation, when the room temperature reachesthe set temperature, the outdoor unit goes off and the indoor unitchanges to whisper fan strength.This is to prevent cold air blowing directly on occupants of theroom.The fan strength will not change even if the button is changed,when another indoor unit is in heating operation.Symptom 5: The fan direction does not correspond to the setting■ The fan direction does not correspond to the remote controldisplay. The fan direction does not swing.This is because the unit is being controlled by the microcomputer.Symptom 6: White mist comes out of a unitSymptom 6.1: Indoor unit■ When humidity is high during cooling operationIf the interior of an indoor unit is extremely contaminated, thetemperature distribution inside a room becomes uneven. It isnecessary to clean the interior of the indoor unit. Ask your dealerfor details on cleaning the unit. This operation requires aqualified service person.■ Immediately after the cooling operation stops and if the roomtemperature and humidity are lowThis is because warm refrigerant gas flows back into the indoorunit and generates steam.Symptom 6.2: Indoor unit, outdoor unit■ When the system is changed over to heating operation afterdefrost operationMoisture generated by defrost becomes steam and isexhausted.Symptom 7: The remote controller display reads "U4" or "U5" and stops,but then restarts after a few minutes■ This is because the remote control is intercepting noise fromelectric appliances other than the air conditioner. This preventscommunication between the units, causing them to stop.Operation automatically restarts when the noise ceases.Symptom 8: Noise of air conditionersSymptom 8.1: Indoor unit■ A "zeen" sound is heard immediately after the power supply isturned on.The electronic expansion valve inside an indoor unit startsworking and makes the noise. Its volume will reduce in aboutone minute.■ A continuous low "shah" sound is heard when the system is incooling operation or at a stopWhen the drain pump (optional accessories) is in operation, thisnoise is heard.■ A "pishi-pishi" squeaking sound is heard when the system stopsafter heating operation.Expansion and contraction of plastic parts caused bytemperature change make this noise.■ A low "sah", "choro-choro" sound is heard while the indoor unitis stopped.When the other indoor unit is in operation, this noise is heard. Inorder to prevent oil and refrigerant from remaining in the system,a small amount of refrigerant is kept flowing. |
Related manuals for Panasonic RXQ10M9W1B
Panasonic U10ME4 Operation Manual
Panasonic RSXP5K7W1 Operation Manual
Panasonic U-5MX3XPQ Operation Manual
Panasonic U-5MX4XPQ Operation Manual
Panasonic CU-5MX1SPP Operation Manual
Panasonic CU-8ME1XPA Operation Manual
Panasonic CU-XE15SKUA Operation Manual
Panasonic PZ2 Operating Instructions Manual
Panasonic K3 Operating Instructions Manual
Panasonic F3 Operating Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine