7SPECIAL REMARKS‘‘DRY’’ Operation • Once the room temperature reaches the level that was set, the unit repeats the cycle ofturning on and off automatically.• In order to prevent the humidity in the room from rising again, the indoor fan also turns offwhen the unit stops operating.• The fan speed is set to ‘‘LO.’’ automatically, and cannot be adjusted.• ‘‘DRY’’ operation is not possible if the outdoor temperature is 59°F (15°C) or less.Heating Performance • Since this air conditioner utilizes outside air for heating, its heating performancedeteriorates as outside temperature decreases. (Due to heat pump system)• It will take some time until the room becomes warmer after heating operation started. (Dueto hot air circulation system in order to heat a whole room)Defrosting • This appliance may start defrosting operation to melt frost form in the outdoor unit duringlong hour heating operation mode.The indoor unit fan will stop for about 5 to 10 minutes at this time.Heating Standby The remote controller shows “ ” (Heating standby) on the display in the following mode andthe indoor unit fan may be controlled.• When operation started (Indoor unit fan stops for maximum 6 minutes.)• When Thermostat activated• When defrosting (Indoor unit fan stops.)Remote Control Sensor The temperature sensor in the indoor unit normally senses the room temperature and can alsosense the ambient temperature of the remote controller.For the details, consult the shop you purchased.Should the power failureoccurs while theunit is runningWhen the unit automatically resumes operation after temporary power failure, it uses the samesettings before the power was cut off.