11.1.1. Display Indication1. Self-check is used to automatically check the bus linecontrolled circuit of the LCD display.2. To get into the Self-check mode, press the volume downbutton on the customer controls at the front of the set, at thesame time pressing the OFF-TIMER button on the remotecontrol, and the screen will show :-If the CCU ports have been checked and found to beincorrectOr not located then " - - " will appear in place of " OK "3. If you want to exit this mode, press stand by button on theremote control or press the Main Power on/off switch at thefront of the set.11 Trouble shooting guide11.1. Self Check11.1.2. Power LED Blinking timing chart1. SubjectInformation of LED Blinking timing chart.2. ContentsWhen an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, thedefective block can be identified by the number of blinkes of the Power LED on the front panel of the unit.3. RemarksAbove Fan function is operated during the fans are installed.33TH-32LHD7UY / TH-32LHD7UXK / TH-32LHD7UXS / TH-32LHD7EK / TH-32LHD7ES / TH-32LHD7BK / TH-32LHD7BS