217.11. Remove the SC-Board1. Remove the SU-Board and SD-Board. (See section 7.9.and 7.10.)2. Unlock the cable clampers to free the cable.3. Disconnect the connector (SC2).4. Disconnect the flexible cable (SC20).5. Remove the screws (×8 ) and remove the SC-Board.7.12. Remove the SS-Board1. Unlock the cable clampers to free the cable.2. Disconnect the connectors (SS11, SS12, SS33 andSS35).3. Remove a short-jumper connector SS34 and re-use fornew SS-Board.4. Disconnect the flexible cables (SS61, SS63, SS64 andSS66).5. Remove the screws (×6 ) and remove the SS-Board.7.13. Remove the Stand brackets1. Remove the Plasma panel section from the servicingstand and lay on a flat surface such as a table (covered)with the Plasma panel surface facing downward.2. Remove the Stand brackets (L, R) fastening screws (×5each) and remove the Stand brackets (L, R).7.14. Remove the D-Board1. Remove the A-Board unit. (See section 7.7.)2. Disconnect the connectors (D3, D5 and D25).3. Disconnect the flexible cables (D20, D31, D32 and D33).4. Remove the screws (×4 ) and remove the D-Board.