243. For leaving the plasma panel from the front frame, pull thebottom of the cabinet assy forward, lift, and remove.4. Remove the spacers and spacer rings (×6 ).7.22. Remove the S-Board1. Remove the Cabinet assy. (See section 7.21.)2. Disconnect the connector (S2).3. Remove the screws (×2 ) and remove the S-Boardmetal frame.4. Remove the screws (×2 ) and remove the S-Board.7.23. Remove the K-Board1. Remove the Cabinet assy. (See section 7.21.)2. Remove the S-Board. (See section 7.22.)3. Remove the screws (×2 ).4. Disconnect the connector (K1) and Remove the K-Board.7.24. Replace the plasma panel (fin-ished)1. Place the new plasma panel (finished) on the flat surfaceof the table (covered by a soft cloth), with the plasmapanel surface facing downward.2. Attach the C1-Board, C2-Board and the C3-Board, con-nect the flexible cables (×15) from the plasma panel to theC1-Board, C2-Board and the C3-Board, and fit the flexi-ble cable holders.3. Attach the Hooks (left, right) and fit the stand brackets (L,R) to the new plasma panel.4. Place the plasma panel section on the servicing stand.5. Attach the cabinet assy and each P.C.Board and so on, tothe new plasma panel.*When fitting the cabinet assy, be careful not to allow anydebris, dust or handling residue to remain betweenthe front glass and plasma panel.