339.2.3. 1080i white balance adjustmentName of measuring instrument Connection Remarks1080i W/ B patternColor analyzer(Minolta CA-100 or equivalent)Component inputPanel surfaceSteps Remarks• Make sure the front panel to be used on the final set is fitted.• Make sure a color signal is not being shown before adjustment.• Put the color analyzer where there is little colour variation.Picture menu : DynamicASPECT : 16:9Adjustment Remarks1. Display the white balance pattern.2. Enter the service adjustment mode.3. A number key [ 1 ] or [ 2 ] are operated and [ WB-ADJ ] is displayed.Check that the color balance is [ COOL ].4. Select [ G-CUTOFF ] item, using the number-key [ 3 ] or [ 4 ], and set to [ 80 ], using thevolume-key [ + ] or [ - ].Also, [ B-CUTOFF ] and [ R-CUTOFF ] set to [ 80 ]5. Set [ G-DRIVE ] at [ E0 ](37 inch / 42 inch), [ D0 ](50 inch).6. Touch the signal receiver of color analyzer to the highlight window's center, and adjust Bdrive and R drive so x, y become the [ COLOR TEMP COOL ] in the below table.7. All RGB drive increase so that the maximum drive value of RGB may become [ FC ].([ ALL-DRIVE ] set to [ FC ].)8. Set colorbalance to [ NORMAL ] using [ 7 ] key.9. Fix G-CUTOFF , B-CUTOFF and R-CUTOFF at [ 80 ].10. Fix G drive at [ E0 ] (37 inch / 42inch), [ D0 ] (50 inch).11. Adjust B-DRIVE and R-DRIVE so the highlight window’s x, y become the [COLOR TEMPNORMAL ] in the below table.12. All RGB drive increase so that the maximum drive value of RGB may become [ FC ].([ ALL-DRIVE ] set to [ FC ].)13. Set colorbalance to [ WARM ] using [ 7 ] key.14. Fix G-CUTOFF , B-CUTOFF and R-CUTOFF at [ 80 ].15. Fix G drive at [ E0 ] (37 inch / 42 inch), [ D0 ] (50 inch).16. Adjust B-DRIVE and R-DRIVE so the highlight window’s x, y become the [ COLOR TEMPWARM ] in the below table.17. All RGB drive increase so that the maximum drive value of RGB may become [ FC ].([ ALL-DRIVE ] set to [ FC ].)Highlight section Signal amplitude 75% Value isHex.