1. Remove the Plasma panel section from the servicingstand and lay on a flat surface such as a table (coveredby a soft cloth) with the Plasma panel surface facingdownward.2. Remove the Hanger metals (L, R) fastening screws (x4^ each) and remove the Hanger metals (L, R).7.13. Remove the Hanger metals7.14. Remove the C1-Board1. Remove the Control button unit. (See section 7.7.)2. Remove the Hanger metal R. (See section 7.13.)3. Remove the flexible cables holder fastening screws (x8<=»■4. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).5. Disconnect the connector (C14).6. Disconnect the flexible cable (C10).7. Remove the screws (x4 and remove the C1 -Board.1. Remove the Tuner unit. (See section 7.4.)2. Remove the Hanger metal L. (See section 7.13.)3. Remove the flexible cables holder fastening screws (x8O ) .4. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).5. Disconnect the flexible cables (C20, C21 and C22).6. Disconnect the connectors (C23 and C25).7. Remove the screws (x4 and remove the C2-Board.7.15. Remove the C2-Board7.16. Remove the Plasma panel section from the Cabinet assy(glass)1. Remove the cabinet assy and the plasma panel fasteningscrews (x2 ^ ) .20