28• Recorder setup menu• Disk selection menu• A – B repeat playback menu• Filter cancellation menu Recorder Instant Playback OperationThe system provides operators with the instant playback operation for a seized global camera. Global Tour Sequences Local Monitor SeizeThe system allows global operators to start and control a tour sequence from another system domain. Before toursequence operation, a local monitor must be seized. Here is the sample procedure to seize local monitor number 1in domain 1:1. Login to System Controller: Enter 500 for ID and enter 500 for password (Global Operator).2. Select monitor 1: Enter 1 and press MONITOR key. Tour Sequence OperationTour sequence operations include start, stop, pause, run, next step, and previous step. Here is the sample to start atour sequence:Run global tour sequence 1(Domain 2’s tour sequence 1):Enter 20010001 and press TOURSEQ key.Notes:• Format: Domain id (2) + Area number (1) +Tour number (1). E.g. 20010001• Only Global Operator can access foreign domain resources.Please note that the first entry digit must be non-zero, and must not exceed 2 digits. Also, the entry will overflow ifthe domain ID entered is greater than 64.The WJ-ASC960 can execute 20 tour sequence steps per second. If the WJ-ASC960 is asked to perform more than20 steps in a single second, it will automatically form 20-step groups, and alternate their execution over a period oftwo or more seconds.