-13-DIP SWITCH SETTINGSIn a configuration, the camera's RS485 data port is used for camera control by the system controller, the camera'sDIP switches must be configured to specify the unit number and communication parameters.You need to set the DIP switches before installing the camera in the ceiling or on a wall.■ Communication Parameters (DIP Switch 2)The factory default settings are all OFF.Switch 1: Terminator (Internal Termination Resistance)Set to ON in the following situations.• When only one camera is connected.• When only one camera is connected via a daisy chain over a longdistance.Switches 2 to 4: Communication ParametersThis setting toggles between 2-line and 4-line communication. Usethese switches to select the communication protocol being used.1 2 3 4ONTerminatorCommunicationParameters1 2 3 4ON4-line Communication1 2 3 4ON2-line Communication1. Attaching and removing the Upper BaseRefer to the installation manual of the mountingbrackets sold separately for removing the UpperBase.2. Remove the protective sticker from the top of thesun shield. (Keep the protective sticker for in step4.)The DIP switches can be set now.3. Set the DIP switches as the following:Communication parameters: Set with switch 2Unit number: Set with switch 14. Put the protective sticker back over the DIPswitches.RS485SettingS TA R TDIP SW1ON1 2 3 4 5 6 7 8DIP SW2ON1 2 3 4SW1SW2Camera top viewProtective StickerDIP Switch