C. Configuration OptionsC-32 March 2001 3160-A2-GB24-10AlrmRelay: DisabNext Enab Disab PrevAlarm Relay. Specifies whether an alarm condition for this circuit card activates the sharedalarm relay on the 3000 Series Carrier. The alarm deactivates if the condition(s) causing itis corrected. An Alarm Cut-Off issued from the SDCP (or PC Emulation program) for aparticular carrier-mounted DSU/CSU also deactivates the alarm. The carrier-mountedDSU/CSU does not reactivate the alarm relay until all alarm conditions for the unit arecleared.The following alarm conditions activate the alarm relay if this configuration option isenabled: Continuous Loss of Signal (LOS) or Out of Frame (OOF) at the network or DTEDrop/Insert (DSX-1) interface. Continuous Out of Frame (OOF) at any synchronous data port that has the EmbeddedData Link enabled. Alarm Indication Signal (AIS) received at either the network or DTE Drop/Insert(DSX-1) interface. Yellow alarm signal received at either the network or DTE Drop/Insert (DSX-1)interface. Excessive Error Rate (EER) detected at the network interface. An Excessive Error Rate (EER) detected at any synchronous data port that has theEmbedded Data Link enabled.NOTE: This configuration option is available on carrier-mounted DSU/CSUs only. Table C-8. Alarm Configuration Options (4 of 4)