WorksheetsA-2 7924-A2-GB20-10PRELIMINARY DRAFTJune 1997DSX-1-to-DSX-1 ConfigurationMultiplexerDSX-1 UnitDSX-1MultiplexerDSX-1 UnitDSX-1Cross-campus2- or 4-wirefacilityCustomer Premises Central Site97-15296To connect two DSX-1-compatible units, configure the units as follows (factorydefaults are in bold):ConfigurationOptionDSX-1-Compatible Unit(Customer Premises)DSX-1-Compatible Unit(Central Site)Card Type CP (default) COLoops Enabled Dual (Loops A & B) orSingle (Loop A)Must be same as CP sideT1 Line Encode B8ZS or AMI Must be same as CP sideFraming D4, Extended Superframe,or UnframedMust be same as CP sideLine Build-Out Enter 5 at the Configcommand prompt. Selectfrom the following options:1) 0 to 133 ft2) 133 to 255 ft3) 266 to 399 ft4) 399 to 533 ft5) 533 to 699 ftEnter 5 at the Config commandprompt. Select from the followingoptions:1) 0 to 133 ft2) 133 to 255 ft3) 266 to 399 ft4) 399 to 533 ft5) 533 to 699 ft