11 of 20598P/599P Application ManualTechnical SpecificationENVIRONMENTAL DATAOperating Temperature 0 to +45°CStorage Temperature -25 to +55°CShipping Temperature -25 to +70°CEnclosure Rating IP20Altitude Rating Maximum Altitude 500 metres.De-rate the Output at 1% per 200 metres.Humidity Maximum 85% relative Humidity at 45°C non-condensing.Atmosphere Non flammable, non-corrosive and dust free.Climatic Class 3k3 as defined by EN60721-3-3 (1995).Safety Designed to : -Europe EN50178 when enclosure mounted.Overvoltage Category IIIPollution Degree 2ELECTRICAL RATINGSCoding Supply Voltage 110 – 240 Vac ±10% 3ph – Low Voltage Build220 – 500 Vac ±10% 3ph – Medium Voltage Build380 – 690 Vac ±10% 3ph – High Voltage BuildField Supply Voltage 110 – 240 Vac ±10% 1ph – Low Voltage Build*220 – 500 Vac ±10% 1ph – Medium Voltage Build*380 – 690 Vac ±10% 1ph – High Voltage Build*The field supply of the 220-500V and 380-690Vac rated products mustbe derived from line-to-line of a 3 phase supply, NOT from line-to-neutral.Supply Frequency 50/60 Hz ±10%Armature ThyristorFiring IsolationSuitable for external stack supply system rated:Overvoltage Category IIIMax. 500Vac rms for Medium Voltage BuildMax. 690Vac rms for High Voltage BuildOutput Current 60 Amps dc naturally cooled - 120 amps dc Force Cooled.De-rate linearly at 1% per °C above rated temperature.Supply CurrentField Coding(1 times Field Current dc value) Amps 1ph ac.Nominal 3ph ac.Field Output Voltage (0.9 times 1ph Supply Voltage) V dcTotal Losses (3 times Idc out) Watts.Auxiliary Supply 110 – 240 Vac ±10% 1ph – Naturally Cooled.110 – 120 Vac ±10% 1ph – Force Cooled 115 Vac Fan configuration.220 – 240 Vac ±10% 1ph – Force Cooled 230 Vac Fan configuration.Auxiliary Supply Current SMPS Quiescent Current – 500mA 115 Vac or 250mA 230 Vac i.e. 50 VA.Fan Current - 270mA @ 115 Vac or 135mA @ 230 Vac.Auxiliary Supply Fuse 3 Amps.FIELD FUSINGDC Output Supply Voltage Semiconductor I2 t Fuse Rating Fuse I2 t Parker SSD PartNo.60 Amps 500 Vac 19100 A 2s 80 amps 2550 A 2s CH570084120 Amps 500 Vac 19100 A 2s 125 amps 8500 A 2s CH57125360 Amps 690 Vac 8830 A 2s 80 amps 2550 A 2s CH570084120 Amps 690 Vac 8830 A 2s 125 amps 8500 A 2s CH571253This manual was downloaded on www.sdsdrives.com+44 (0)117 938 1800 - info@sdsdrives.com