DOC-0017-03-EN: AC15 Series - Hardware Installation ManualDOC-0017-03-EN-B 04.04.2023 27 (125)3ø, 230V Products:FrameSize Product CodeMotorPower(kW)J1 ‘EMC’ (ACLine Y-Cap)Link:Y1 ‘VAR’ (VDR)Link:J2 ‘P -> PE’ (DCLink Y-Cap)Link:115G-31-0025... 0.37 x15G-31-0045... 0.75 x15G-31-0070... 1.5 x2 15G-32-0100... 2.2 x3 15G-33-0170... 4 x 4 15G-34-0210... 5.5 x x5 15G-35-0300... 7.5 x x15G-35-0400... 11 x x3ø, 400V Products:FrameSize Product CodeMotorPower(kW)J1 ‘EMC’ (ACLine Y-Cap)Link:Y1 ‘VAR’ (VDR)Link:J2 ‘P -> PE’ (DCLink Y-Cap)Link:115G-41-0012… 0.37 x15G-41-0020... 0.75 x15G-41-0040... 1.5 x2 15G-42-0065... 2.2 x15G-42-0090... 4.0 x3 15G-43-0120... 5.5 x15G-43-0170... 7.5 x4 15G-44-0230... 11 x15G-44-0320... 15 x515G-45-0380... 18.5 x15G-45-0440... 22 x15G-45-0600... 30 xApproximate Link Locations:Note: Link positions vary slightly between products. Image shows approximate link locations:To access the links, it is necessary to open the product:1. Remove:- Frame 1: 3x Power Stack cover fixings (1x top, 2x bottom) from the product- Frames 2 – 5: 4x Power Stack cover fixings (2x top, 2x bottom) from the product.2. Carefully lift the power stack cover with the control module attached - just enough to adjust the linkpositions. Removing the link completely is the same as placing the links in the ‘disconnected’ (pin 2– 4) position.Note: All power cables must be removed from the product to access the links.J2 DC LinkY-Cap LinkJ1 ‘EMC’ ACLine Y-Cap &Y1 ’VAR’VDR Links