INSTALLATION • OEM650/OEM650X10Quick Test: OEM650 with Separate Indexer1. Complete steps 1- 6 from the OEM650 Quick Test, but do notremove jumper #11 (Auto Test Function).2. To connect a Compumotor indexer to the OEM650’s 25-pin Dconnector refer to Figure 2-6.To connect a non-Compumotor indexer to the OEM650's 25-pinD connector, refer to Figure 2-7.3. Apply power. The OEM’s green power LED should be on. If thered FAULT LED is on, consult Chapter 5, Troubleshooting.This test assumes that your indexer’s motor resolution is set to25,000 steps/rev. This is the default motor resolution settingfor the OEM650.4. Using the indexer, send step pulses to the drive that will rotate themotor one CW revolution (25,000 step pulses) at 1 rps (25,000steps per second).5. Using the indexer, send step pulses to the drive that will rotate themotor one CCW revolution at 1 rps. The drive's default directionis CCW (i.e., if the the direction input is not activated, the motorwill rotate CCW—if the direction input is activated, the motor willrotate CW). If the motor does not rotate in the desired direction,reverse the direction sense for your system by reversing the leadsgoing to the A+ and A- terminals.WARNINGNever connect or disconnect any component to or from the drive with powerapplied. System damage or personal injury may occur.6. After verifying that the motor moves CW and CCW, turn off power.❐ Disconnect cables and resistor.