4 Parker HannifinPump and Motor DivisionTrollhättan, SwedenService ManualSeries F11Bulletin HY30-5503-M1/UK1) Intermittent: max 6 seconds in any one minute.2) Self priming speed valid at sea level.SpecificationsSize F11 -5 -6 -10 -12 -14 -19Displacement (cm3/rev) 4,9 6,0 9,8 12,5 14,3 19,0Operating Pressure (bar)Max intermittent 1)Max continuous420350420350420350420350420350420350Motor operating speed (rpm)Max intermittent 1)Max continuousMin continuous1400012800501120010200501120010200501030094005099009000508900810050Max pump self priming speed (rpm)L or R operation 2) 4600 - 4200 3900 3900 3500Motor input flow (l/min)Max intermittent 1)Max continuous69636761110100129118142129169154Main circuit temp.Max (°C)Min (°C)80-4080-4080-4080-4080-4080-40Mass moment of inertia (x10 -3) (kg m2) 7,8 9,5 15,6 19,8 22,7 30,2Weight (kg) 4,7 7,5 7,5 8,2 8,3 11Operating temperatureThe following temperatures should not be exceeded(Type N shaft seals): Drain fluid: 90 °C.FPM shaft seals (type V) can be used to 115 °Cdrain fluid temperature.Note: The temperature should be measured at theutilized drain port.Continuous operation may require case flushing inorder to meet the viscosity and temperature limitations.For further information we refer to:Catalogue HY30-8249/UK