32IQAN-MC31 Technical OverviewAppendix AInstruction book, IQAN-MC31Appendix AIQAN-MC31 Technical OverviewAbsolute Maximum Ratings aa.The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be subjected without damage. This doesn´timply that the device will function at these extreme conditions, only that, when these conditions are removed and the device operated with-in the “Recommended Operating Conditions”, it will still be functional and its useful life wonít have been shortened.Ambient temperature, -40 to +85 °CStorage temperature -40 to +100 °CVoltage supply on +BAT 6 to 36 VdcVoltage on any pin with respect to -BAT 36 VdcPower driver load Total load on power drivers < 20AEnvironmental ratingsClimate environmentEnclosure, water & dust protectionSalt mistDamp heat, cyclicDamp heat, steady stateHeat, operationHeat, storageColdChange of temperatureIEC 60529:2001, IP67; DIN 40050 Part 9:1993, IP6K9KIEC 60068-2-52:1996 Kb, 72 hIEC 60068-2-30:2005 Db, +55°C, 95% RH, 6 cyclesIEC 60068-2-78:2001 Cab, +40°C, 93% RH, 21 daysIEC 60068-2-2:2007 Bb, +85°C, 72 hoursIEC 60068-2-2:2007 Bb, +100°C, 72 hoursIEC 60068-2-1:1993 Ab, -40°C, 16 hoursIEC 60068-2-14:1984 Nb, - 30°C to +70°C, 100 x 4 hoursMechanical environmentRandom vibrationBumpIEC 60068-2-64: 2008 Fh, 10 - 1000 Hz, 11.6 Grms, 3 x 10 hIEC 60068-2-27:2008 Ea, 40 g, 6 ms, 1000 * 6 dirEMCRadiated emissionConducted emissionConducted susceptabilityRadiated susceptabilityConducted transients susceptabilityESD, operationESD, handlingISO 13766/ISO 14982EN 55025:2003, 0.15-108 MHz, Class 1ISO 11452-4:2005, 1 - 200 MHz, 1 kHz, 80% AM, 100 mAISO 11452-2:2004, 200-2000 MHz, 1kHz, 80% AM, 100 V/mISO 7637-2:2004, Pulse 1,2a,2b,3a,3b,4,5, Level 3ISO 7637-3:2007, Level 3ISO 10605:2008, 8kV (contact), 15kV (air)ISO 10605:2008, 8kV (contact)Markings/ApprovalsCE 2004/108/EC, EMC directive2011/65/EU, ROHS 2