8Mounting the module5 MountingInstruction book, IQAN5 MountingMounting the moduleThe IQAN module should be mounted according to the following instructions:• Locate the module eliminating the risk for the cabling to be folded, crushed or dam-aged in any way. Ensure the cabling cannot pull, twist or induce sideload on the con-nector.• Locate the module so that severe physical impact is avoided, e.g impact from fallingobjects or the module being used as a step.• Locate the module so that air can circulat to eliminate excess heat. Ensure that noexternal heat, e.g. from the engine or heater, is transferred to the module.• Locate the module to protect it from high pressure washing or similar.• Locate the module so that the cable connector is facing down .• Locate the module so that the LEDs are visible.Non approved placing.N OTICEThe IQAN module must not be placed in any marine related or similar continuouslydamp, salt-spray environment without external protection.Assembling of the ID-TagThe ID-Tag will be placed in the connector in order to address/ terminate the module.For IQAN master modules, the use of an ID-tag is application dependant. All IQANexpansion modules require an ID-tag, ref section "Addressing/terminating".The ID-Tag will be mounted under the connector casing. Bend the ID-Tag’s wirestoward the opposite side of where the other wires enter the connector.Assembling of the Id-Tag.