HD7871/60 / HD7871/615-11Boiler reset:Boiler-reset-step 0 Entry to boiler reset mode:1. Connect mains;2. After 0.5 second and before 1.5 second operate the1-cup button.3. Release all switches.Settings:Manual pump calibrationPlease note that the volume adjustment to compensate for adifferent country execution is now split in Volume adjustment(calibrate Regular coffee cup volume) and the Countryselection (set the corresponding Strong coffee cup volume).Service-step 0 Entry to calibration mode:1. Connect mains;2. After 0.5 second and before 1.5 second operate the1-cup and 2-cup buttons simultaneously.On/off, 1-cup and 2-cup LEDs will be switched ON.3. Release all switches.Service-step 1A Decrease calibration value:1. Push (and release) the 1-cup button to decrease thecalibration value.The On/Off LED will be OFF for 0.5 seconds.2. Repeat step 1A.1 when required.Service-step 1B Increase calibration value:1. Push (and release) the 2-cup button to increase thecalibration value.The On/Off LED will be OFF for 0.5 seconds.2. Repeat step 1B.1 when required.Service-step 2 Store calibration value:1. Operate the On/Off button.On/Off LED will blink fast for 1.0 seconds and thecalibration value is stored.2. Release all switches.The On/Off and 1-cup LED will be ON.The memory LED will be OFF when ME is selected andON when HE is selected.ME/HE selectionIn this appliance ME (Mid-End) should be selected;Strong LED off.Service-step 3 Change HE/ME selection value:1. Push (and release) the 1-cup button to change theHE/ME value.The strong LED will be OFF when ME is selected andON when HE is selected.2. Repeat step 3.1 when required.Service-step 4 Store HE/ME selection value:1. Operate the On/Off button.On/Off LED will blink fast for 1.0 seconds and theHE/ME value is stored.2. Release all switches.The On/Off LED will be OFF.Country selectionService-step 5 Change country selection value:1. Push (and release) the 2-cup button to change thecountry value.The regular LED will be OFF when a European selectionis selected and ON when a France selection is selected.Note that when changing the country selection the pumpneeds to be recalibrated again with a defined pump time.2. Repeat step 5.1 when required.Service-step 6 Store country selection value:1. Operate the On/Off button.On/Off LED will blink fast for 1.0 seconds and thecountry selection value is stored.2. Release all switches.Service-step 7 Select XL water tank (1.6L) or normalwater tank (0,93L) version:1. Push (and release) the 1-cup button to change thewater tank size.Toggle LED Off = normal watertank.Toggle LED On = XL watertank.2. Repeat step 7.1 when required.* For the HD7873 with BRITA MAXTRA water filter pleaseselect per default normal water tank.Service-step 8 Store XL / normal water tank value:1. Operate the On/Off button.On/Off LED will blink fast for 1.0 seconds and the watertank selection value is stored.2. Release all switches.All LEDs will be OFF.When settings have been changed to change the coffeevolume (Manual pump calibration or Country selection), theappliance needs to be unplugged from the mains before thenew settings will take effect.Repair instruction