BMC S ERIAL O VER LAN4-3 Obtain Field Replaceable Unit (FRU) information Obtain System Event Log (SEL) entries Obtain Sensor Data Records (SDR) Set Platform Event Filtering (PEF) Set LAN configurationsIn addition, the BMC supports LAN alerting in the form of SNMP traps that conform to theIPMI Platform Event Trap (PET) format.Session and UserThis BMC supports ten (10) user accounts. Each can have a different user name, passwordand privilege level. Four accounts can login simultaneously. The available user privilegelevels are User, Operator, and Administrator.Serial Over LANBMC supports 1 IPMI (Spec v2.0) specific SOL session. BMC supports redirect data fromUART interface.Time SyncIn BMC design, BMC does not have a local RTC to know what time it is. Each time BMC willget the current time from system PCH after BMC boot. The current time is updated period-ically from the PCH. The remote console program interpret this time as pre-initial.SELBMC supports IPMI 1.5/2.0 standard SEL operation. It can keep SEL log. Event happened inBIOS side will be logged by using Add SEL Entry command. BMC will store them in FLASH,the time stamp field will be filled by BMC. When SEL is full, the new SEL won’t be loggedbut will go through PEF as usual. If AC powers off, all SELs will remain in NV.Platform EventPlatform Event FilterThe BMC implements selectable action on an event or LAN alerting base on event. Bydefault, no any PEF entries or actions exist, applications need to configure it to enable. Dedicated and Shared NIC The policy to match an event to Platform Event Filter Table entry is IPMI 1.5 standard.