EN.9. Z-Wave ExclusionZ-WAVE EXCLUSION1. Connect the module to the power supply2. Make sure the module is within direct range of your Z-Wave controller or use a hand-held Z-Wave remote to perform exclusion3. Enable exclusion mode on your Z-Wave controller4. Toggle the switch connected to the I1 terminal 3 times within 3 secondsORPress and hold the S (Service) button for 2 to 6 seconds5. The module will be excluded from your network but any custom configuration parameterswill not be erased.FACTORY RESET1. Connect the module to the power supply2. Within the first minute the module is connected to the power supply, toggle the switchconnected to the I1 terminal 5 times within 3 secondsORPress and hold the S (Service) button for at least 6 secondsBy resetting the module, all custom parameters previously set on the module will return totheir default values, and the owner ID will be deleted. Use this reset procedure only when themain controller is missing or otherwise inoperable.ā By resetting the module, all custom parameters previously set on the module will returnto their default values, and the owner ID will be deleted. Use this reset procedure only whenthe main controller is missing or otherwise inoperable.