14 7021-154J May 12, 2017CASTILE F R E E S TANDINGI. Pellet Venting ChartsFigure 14.1Fire Risk.• Only LISTED venting components may be used.• NO OTHER vent components may be used.Substitute or damaged vent components may impairsafe operation.WARNINGThe maximum horizontal venting allowed with no vertical vent-ing attached is 48 inches (1219mm) including one 90° elbowor two 45° elbows. This is our recommended horizontal vent-ing installation. Addition of any horizontal venting beyond 48inches (1219mm) Hearth & Home Technologies strong recom-mends a minimum of 60 inches (1524mm) of additional ver-tical vent. Horizontal sections of vent pipe should have a 1/4inch (6.35mm) rise per foot.Hearth & Home Technologies recommends any installationrequiring more than two 90° elbows, or more than 15 feet(4.5m) of venting to use 4 inch (102mm) vent.NOTICE: These are guidelines for successful venting of your pellet appliance. The more vertical rise you can obtain inyour system, the better it will perform. Horizontal vent runs can accumulate ash and will need to be cleaned more often.Try to keep them as short as possible.ONE 90º ELBOWTotalHorizontalMinimumVerticalVentDiameter4 0 35 5 36 6 37 7 38 8 49 9 410 10 411 11 412 12 413 13 414 14 415 15 416 16 417 17 418 18 419 19 4see fig. 14.1TWO 90º ELBOWSTotal Minimum VentHorizontal Vertical Diameter2 5 33 6 34 7 35 8 36 9 37 10 48 11 49 12 410 13 411 14 412 15 413 16 414 17 415 18 4see fig. 14.2THREE 90º ELBOWSTotal Minimum VentHorizontal Vertical Diameter2 11 43 12 44 13 45 14 46 15 47 16 48 17 49 18 410 19 411 20 4see fig. 14.345° elbow is equivalent to 1 foot (30.48cm) of straight pipe90° elbow is equivalent to 3 feet (91.44cm) of straight pipeMinimum Vertical Vent for One Elbow051015200 5 10 15 20Horizontal Run, (ft)Minimum Vertical Rise(ft)Minimum Vertical Vent for One ElbowFigure 14.3Minimum Vertical Vent for Three Elbows05101520250 2 4 6 8 10 12Length of Horizontal Sections (ft)Minimum Vertical Rise(ft)Minimum Vertical Vent for Three ElbowsFigure 14.2Minimum Vertical Vent for Two Elbows051015200 5 10 15Length of Horizontal Sections, (ft)Minimum VerticalRise, (ft)Minimum Vertical Vent for Two Elbows