Page 13Cumberland Gap Wood StoveRSeptember 1, 2008 7006-188EFigure 13BSOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLEAdd the 25" (635mm), center-line measurement to thedepth measurement of your floor protector. Mark thiscombined measurement at the correct wall locationfor your installation, maintaining minimum clearanceto combustibles. FLOOR PROTECTORTHIMBLE,12" (305mm)OF BRICKAIRTIGHTCLEANOUT DOORSHEATHINGCEILING JOISTCOMBUSTIBLE WALL1" (25mm)CLEARANCEFIRECLAY FLUE LINERWITH AIR SPACEEAVE1" (25mm)CLEARANCEWITH FIRESTOPRAFTERFLASHINGCONCRETE CAPFor the method of installation to a masonry chimney shown in Figures 14A & 14B on page 14, it will be necessary to purchase a12" (305mm) long (8" (203mm) inside diameter), section of prefabricated listed solid pack chimney to use as a thimble. Purchasea wall spacer, trim collar, and a wall band manufactured to fit the chimney section you purchase.The safety features of this system are two fold: 1) A 2" (51mm) air space between the chimney section and combustible wall; and, 2)The 1" (25mm) air space around the chimney connector as it passes through the chimney section to the chimney.The location of the opening through the wall to the chimney must leave a minimum 18" (457mm) vertical clearance between theconnector pipe and the ceiling to prevent the ceiling from catching fire.Measure as shown in Figure 13A. Cut an opening in the wall large enough to accommodate the outside dimension of the chimneysection plus the minimum air space specified by its manufacturer. It may be necessary to cut the wall studs and install a headerand a sill frame to maintain the wall support. The hole in the chimney must have at least an 8" (203mm) diameter fire clay lineror equivalent, secured with refractory mortar. If it is necessary to cut a hole in the chimney liner, use extreme care to keep it fromshattering.WARNING! ALWAYS FOLLOW CHIMNEY CONNECTOR MANUFACTURER’S INSTRUCTIONS FOR PROPER INSTALLATION.CHIMNEY CONNECTOR IS TO BE USED ONLY WITHIN THE ROOM, BETWEEN THE STOVE AND CEILING OR WALL, NEVERPASSING THROUGH A COMBUSTIBLE CEILING OR WALL. THE CONNECTOR SHALL NOT PASS THROUGH AN ATTIC ORROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING. MAINTAIN MINIMUM CLEARANCESTO COMBUSTIBLES AS REFERENCED ON PAGES 6 & 7.Figure 13ACenter of HoleWallCenter LineOpeningCenter LineCL25.0"(635mm)NOTE: ALL HORIZONTAL INSTALLATIONS REQUIRE ACCESSORY HORIZONTAL FLUE SHIELD, PART HTSHLD-7006,TO COMPLY WITH REQUIRED CLEARANCES.NOTE: OPTIONAL FIRE SCREEN, PART SCR-7006, CAN ONLY BE USED IN FULL VERTICAL INSTALLATIONS.