Quadra-Fire MT VERNON Owner's Manual
Contents
|
2 7036-187M August 13, 2018MT. VERNON AE INSERTITEM PART NUMBER PART NASAFETY LABEL / ÉTIQUETTE DE SÉCURITÉListed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile HomeInstallation. This appliance has been tested and listed for use in ManufacturedHomes in accordance with OAR 814-23-9000 through 814-23-909.RMt. Vernon Pellet Insert AEMINIMUM CLEARANCES TO COMBUSTIBLE MATERIALSMasonry or Zero ClearanceAS A BUILT-IN UNITJAN FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC7036-137_R9A Insert side to combustible / Insérez le côté au mur combustible latéralB Insert top to face trim / Insérez le dessus de la garniture de façadeC Insert side to face trim / Insérez le côté de la garniture de façadeD Hearth extension from door opening / Prolongement d’âtre depuis l’ouverture de la porte devantE Hearth extension from side of door opening / Prolongement d’âtre depuis le côtéde l’ouverture de la porte6 in. 152mm0 in. 0mm0 in. 0mm6 in. 152mm6 in. 152mmNE PAS ENLEVER L'ÉTIQUETTEReport / Rapport#061-S-69-6Fabriqué par :CAUTION:ATTENTION:HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKINBURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit only with fuel hopper lid closed. Failure to do somay result in emission of products of combustion from the hopper under certain conditions. Maintain hopperseal in good condition. Do not overfill hopper.CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACEDÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LESINSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter,sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:A Des Conduits Du Haut/Arrières: 3 in. (76mm)B Des Conduits Du Haut/Arrières: 2 in. (51mm)C Des Conduits Du Haut: 7.5 in. (191mm)Arrières 2.75 in. (70mm)D Des Conduits Arrières/Du Haut 3 in. (76mm)E Côté de Fonte au Mur Latéral: 6 in. (152mm)A Top of Hopper Top/Rear Vent 3 in. (76mm)B Side of Outside Skin Top/Rear Vent 2 in. (51mm)C Back of Hopper Top Vent 7.5 in. (191mm)Rear Vent 2.75 in. (70mm)D Vent Pipe to Combustible Top/ Rear Vent 3 in. (76mm)E Cast Side to Side Wall Top/Rear Vent 6 in (152mm)Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dansl'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l 'usagedans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.352 Mountain House Road, Halifax, PA 17032BDCCABECOMME APPAREIL INSÉRÉ0 in. Clearance To Exposed Section and Face Trim / Espace librede 0 mm de la section expos é e et de la garniture du devant.SIDE WALLMANTELABDCEFace Trim2017 2018 2019Dégagement de la maçonnerie ou Dégagement zéro*MUR LATÉRALGarniturede façadeMANTEAUDO NOT REMOVE THIS LABELManufactured by:See manual for mantel clearances.www.quadrafire.comO-T LTested andListed byPortlandOregon USAOMNI-Test Laboratories, Inc.C USMade in U.S.A. of US andimported parts.Fabriqué aux États-Unis-d’Amérique par despièces d’origine américaine et pièces importées.PREVENT HOUSE FIRESInstall and use only in accordance with manufacturer's installation and operating instructions.Contact local building or fire officials about restrictions and inspection in our area.WARNING: FOR MOBILE HOMES: Do not install appliance in a sleeping room. Anoutside combustion air inlet must be provided. The structural integrity of the mobile homefloor, ceiling and walls must be maintained.Refer to manufacturer's instructions and local codes for precautions required for passingchimney through a combustible wall or ceiling. Inspect and clean vent system frequentlyin accordance with manufacturer's instructions.DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.Use a 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system.Tested to: ASTM E1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room Heating PelletBurning Type, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD. SEE OWNER’SMANUAL FOR OTHER FUEL OPTIONS.OMNI-Test Laboratories, Inc. has determined that this appliance complies withCanadian Standards Association (CSA) B415.1 and Title 40 of the U.S. Code ofFederal Regulations, Part 60, SubPart AAA.OMNI-Test Laboratories Accrediations:The Standards Council of Canada, the American National Standards Institute, and theU.S. Environmental Protection Agency.I nput Rating: 53,300 BTU/HR.Electrical Rating: 115 VAC, 60 Hz, Start 5 Amps, Run 1.25 AMPS.Route power cord away from unit. Do not route cord under or in front of appliance.DANGER: Risk of electrical shock. Disconnect power supply before servicing.Replace glass only with 5mm ceramic available from your dealer.To start, set thermostat above room temperature, the stove will light automatically. Toshutdown, set thermostat to below room temperature. For further instruction refer toowner's manual.Keep viewing and ash removal doors tightly closed during operation. PRÉVENTION DES FEUX DE MAISONInstallez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le bureaude la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation dansvotre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une chambre à coucher. Un tuyau extérieur decombustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structureintégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.Référez vous aux instructions du fabricant et des codes locaux pour les précautions requises pour passer unecheminée à travers un mur ou un plafond combustibles, et les compensations maximums.Inspectez et nettoyez la cheminée fréquemment.NE PAS CONNECTER CETTE UNITÉ À UN CONDUIT DE CHEMINEE DESSERVANT UN AUTRE APPAREIL.Utilitsez le syst è me de ventilation de 3 or 4 inch (76-102mm) de diametre de type “L” ou “PL”.Testé à: ASTM #1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room Heating. Pellet Burning Type,UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS. VOIR LE MANUAL DU PROPRIÉTAIREPOUR D’AUTRES OPTIONS DE CARBURANT.OMNI-Test Laboratories, Inc. a déterminé que cet appareil se conforme avec la norme de l’AssociationCanadienne de normalisation (CSA) B415.1 ainsi que le Titre 40 du Code Fédéral de Régulations desÉtats-Unis, partie 60, sous-partie AAA. Accréditations OMNI-Test Laboratories : Le Conseil Canadiendes Normes (CCN/SCC), l’Institue des Standards Nationaux Américain (ANSI) et l’Agence de ProtectionEnvironnemental (EPA).Puissance de Rendement: 53,300 BTU/HRPuissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps,Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil.DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service.Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumeraautomatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de lapièce. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouvertureet la porte des cendres fermées hermétiquement durant l'opération.*When constructing floor protection for your pellet appliance, any parts or materials used, must be non-combustible.* Lors de la construction de protection de sol pour votre appareil à granules, toute pièces ou matériaux utilisés, doivent être incombustibles.U.S. ENVIRONMENTAL PROTECTION AGENCYCertified to comply with 2015 particulate emission standards at 1.7 g/hrEPA Method 28 and 5G. Not approved for sale after May 15, 2020This wood heater needs periodic inspection and repairfor proper operation. Consult the owner’s manual forfurther information. It is against federal regulations tooperate this wood heater in a manner inconsistent withthe operating instructions in the owner’s manual.Serial No. / N° de sérieHF BARCODE LABELA. Sample of Serial Number / Safety LabelLOCATION: Back of ApplianceNOTE: Clearances may only be reduced by means approvedby the regulatory authority having jurisdictionand Welcome to the Quadra-Fire Family!Serial No.ModelNameTest Lab &Report No.Mfg. DateSAMPLE |
Related manuals for Quadra-Fire MT VERNON
Quadra-Fire Mt. Vernon Series Owner's Manual
Quadra-Fire MTVERNON-AE-CSB Owner's Manual
Quadra-Fire PS35-C Owner's Manual
Quadra-Fire MTVI-E2-MBK Owner's Manual
Quadra-Fire HUDBAY-FS Owner's Manual
Quadra-Fire SAPPHIRE-MBK Owner's Manual
Quadra-Fire 4300 Series Owner's Manual
Quadra-Fire COLBAY-FS-B Owner's Manual
Quadra-Fire QFI30FB-IFT Owner's Manual
Quadra-Fire SAPH-MBK-IPI Owner's Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine