6 Pub. No. 2200772355 — October 2006FIGURE 5 — INSTALLATIONCONNECTION TO THE COMPRESSED AIRSYSTEMFit a manual shut-off valve between the machine and thecompressed air system so that the dryer may be isolatedduring maintenance operations. Drainage of condensate(automatic) passes outside the machine through a flexibletube (2 in Figure 6) that may be inspected. Drainage mustcomply with local codes.ALL DAMAGE DUE TO THE FAILURE TO COMPLYWITH THESE INSTRUCTIONS CANNOT BEATTRIBUTED TO THE MANUFACTURER AND MAYINVALIDATE THE GUARANTEE.FIGURE 6 — CONDENSATE PIPEDIMENSIONS AND TECHNICAL DATAFIGURE 7 — DIMENSIONSFIGURE 8 — CONNECTION1ATTENTION:Dryer must be wired to the powersupply through a fused disconnectswitch or circuit breaker inaccordance with national andlocal electrical codes.Minimum 24 in (0.6 m)on all sides.2Type Lin (mm)Win (mm)Hin (mm)QPNC 10 13.78 (350) 20.09 (510) 19.05 (484)QPNC 15 13.78 (350) 20.09 (510) 19.05 (484)QPNC 25 13.78 (350) 20.09 (510) 19.05 (484)QPNC 35 13.78 (350) 20.09 (510) 19.05 (484)QPNC 50 13.78 (350) 20.09 (510) 19.05 (484)HWLType ANPTBNPTQPNC 10 1/2-14 Male 1/2-14 MaleQPNC 15 1/2-14 Male 1/2-14 MaleQPNC 25 1/2-14 Male 1/2-14 MaleQPNC 35 1/2-14 Male 1/2-14 MaleQPNC 50 1/2-14 Male 1/2-14 Male(A) AIR INLETCONDENSATEDRAINING(B) AIR OUTLET ELECTRICAL CABLE