4-10 P/N 480-0062-00-14Chapter 4: Advanced Topic: Diagnostics/Maintenance3. Type reset. You will be asked if you are sure you want to set the unit back to factory defaults.4. Type yes to confirm (type no to cancel the restore).Change PasswordFor security purposes, you may want to change the password. You can change the password viaCommand Line Interface (CLI) as follows:1. Access the CLI through a Telnet session. See the Command Line Interface (CLI) guide for moreinformation.2. Access the Maintain# module.3. Type password. A prompt will ask you for the old password.4. Type the old password and press Enter. A prompt will ask you for the new password. Type thenew password and press Enter. A confirmation will ask you to confirm the new password.5. Re-type the new password and press Enter.A message will tell you the password was changed successfully.Change Unit Date and TimeYou can change the unit’s date and time via Command Line Interface (CLI) as follows:1. Access the CLI through a Telnet session. See the Command Line Interface (CLI) guide for moreinformation.2. Access the Config module.3. Type date followed by mm/dd/yy/hh:mm:ss and press Enter.4. For example, type config# date 06/14/04/22:14:00. This command will set the current time toJune 14, 2004 at 10:14 p.m.VoIPon www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299