12US English User Manual for RAIS Rondo, RAIS Mino II and RAIS Mino II SoapstoneClearance to combustible wallsTo find out whether the wall by which the stove is to be placed iscombustible or not, please contact your architect or the local buildingauthorities.If the floor is combustible, the stove must be placed on a non-com-bustible plate such as steel, glass or stone.Ref. Description Minimum clearenceA Sidewall to unit 13” (33 cm)B Backwall to unit 6.5” (16.5 cm)C Cornerwall to unit 6” (15.2 cm)D Sidewall to connector 20” (50.8 cm)E Backwall to connector 12” (30.5 cm)F Cornerwall to connector 14” (35.6 cm)G Ceiling to appliance 43,5” (111 cm)H Backwall to unit 13” (33 cm)I Backwall to connector 20” (50,8 cm)J Sidewall to unit 34” (86,4 cm)K Sidewall to connector 41” (104 cm)L Distance to frontwall/furnishing 34” (86.4 cm)M Cornerwall to connector 41” (104 cm)Clearance to non-combustible wallWe recommend a minimum clearance to non-combustible material ofat least 50 mm so that cleaning is easy. The cleaning door should beaccessible at all times.Clearances may only be reduced by means approved by the regulatoryauthority.**:Please refer to NFPA guide-lines in USA and CAN/CSAB365-M91 in Canada.